1.2 Preliminary checks
a
WARNING
Should it be necessary to access the areas in the
bottom part of the appliance, make sure that the
system components and pipes are not hot (risk of
burning).
Before replenishing the heating system, put on pro
-
tective gloves.
Commissioning of the
Brava Slim HE R
boiler must be carried
out by professionally qualified technicians, after which the boil-
er can operate automatically. It may, however, be necessary for
the user to start the appliance autonomously without involving a
technician: for example, after a holiday.
First of all check that the gas isolation and water system valves
are open.
1.3 Ignition
After having carried out the preliminary checks, perform the
following to start the boiler:
set the main system switch to "ON" in order for the display to
show the pressure level in the system during refilling
make sure that the operating mode is set to "Stand-by";
if this is
not the case, press the button
y
until "Stand-by" mode has
been selected
ON
Fig. 3
on the display (1), check that the heating system pressure
when cold is
1-1.2 bar (100-120 kPa)
. Otherwise, open the fill-
ing valve, which is to be prearranged on the system return,
and fill until a pressure of
1-1.2 bar (100-120 kPa)
is shown on
the display (1)
close the filling valve
1
Fig. 4
select the "WINTER"
l
operating mode by pressing the
y
button twice. the value of the delivery sensor detected at
that moment will appear on the display
set the room thermostat to the required temperature, or if
the system is equipped with a timed programmer or external
temperature controller, check that this is ON and set accord
-
ingly.
1.4 Adjusting the heating temperature
If the heating temperature is to be increased or decreased,
press the button
t
followed by the buttons
>
or
<
until the de-
sired temperature is reached. The temperature can be set to
between 20 and 80°C.
1.5 Fault / malfunction codes
If a fault/malfunction is detected during boiler operation, the
message
"ALL"
will appear on the display followed by the fault
code.
If you see alarm
“02”
(low water pressure in the system):
on the display (1), check that the heating system pressure
when cold is
1-1.2 bar (100-120 kPa)
. Otherwise, open the fill-
ing valve, which is to be prearranged on the system return,
and fill until a pressure of
1-1.2 bar (100-120 kPa)
is shown on
the display (1)
press and hold the button
y
for more than 3 seconds and
check whether normal operating conditions are restored
close the filling valve
1
Fig. 5

Table of Contents

Other manuals for Sime BRAVA SLIM HE R Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sime BRAVA SLIM HE R Series and is the answer not in the manual?

Sime BRAVA SLIM HE R Series Specifications

General IconGeneral
BrandSime
ModelBRAVA SLIM HE R Series
CategoryBoiler
LanguageEnglish

Related product manuals