EasyManua.ls Logo

Simer 3325E - User Manual

Simer 3325E
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OWNER’S MANUAL
Convertible Deep Well JetPumps
NOTICE D’UTILISATION
Pompe à éjecteur transformables
pour puits profonds
MANUAL DEL USUARIO
Bombas convertibles de chorro
para pozos profundos
2760 0197
© 2011 SIM918 (4/20/11)
3325E, 3327E
1543 0311
3305P, 3307P, 3310P
Installation/Operation/Parts
For further operating, installation, or
maintenance assistance:
Call 1-800-468-7867
English. . . . . . . . . . . Pages 2-16
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le 1 (800) 468-7867
Français. . . . . . . . . Pages 17-31
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-468-7867
Español . . . . . . . Paginas 32-48
293 Wright Street, Delavan, WI 53115
Phone: 1-800-468-7867
Fax: 1-800-390-5351
Web Site: SimerPump.com

Questions and Answers

  • S
    samantharoachAug 10, 2025
    What to do if my Simer 3325E Water Pump motor will not run?
    • D
      Dylan TaylorAug 10, 2025
      If your Simer Water Pump motor isn't running, several factors could be at play. First, ensure the disconnect switch is turned on. If it is on, check the fuse and replace it if it's blown, or reset the circuit breaker if it has tripped. A defective starting switch could also be the culprit, in which case you should disconnect the power and replace the starting switch. Also, inspect the wires at the motor for looseness, disconnections, or incorrect wiring, referring to the wiring instructions. Remember to disconnect power before checking and tightening any wiring. If the pressure switch contacts are dirty, disconnect the power and file the contacts with an emery board or nail file.
  • J
    jameskellerAug 20, 2025
    What to do if Simer 3325E Water Pump motor runs hot?
    • K
      Kenneth WolfAug 20, 2025
      If your Simer Water Pump motor runs hot and the overload kicks off, it could be due to incorrect wiring. Refer to the wiring instructions to ensure proper setup. Additionally, low voltage can cause the motor to overheat. Check with your power company and consider installing heavier wiring if the current wire size is too small, consulting the Electrical/Wiring Chart for guidance.
  • C
    Catherine MyersAug 26, 2025
    Why is my Simer 3325E Water Pump not delivering water to full capacity?
    • A
      Allison BowmanAug 26, 2025
      If your Simer Water Pump isn't delivering water to its full capacity, it could be due to a few reasons. The water level in the well might be lower than estimated, potentially requiring a new nozzle and venturi combination. If you're using steel piping, it might be corroded or limed, causing excess friction; consider replacing it with plastic pipe where possible, or with new steel pipe. Also, the piping might be too small in size, so consider using larger piping.
  • R
    Robert LeblancSep 4, 2025
    Why is air spurting from the faucets when I use my Simer 3325E Water Pump?
    • K
      Karen IngramSep 4, 2025
      If you're experiencing air spurts from your faucets when using your Simer Water Pump, it could be due to several reasons. The pump might be in the process of picking up prime; once it does, it should pump solid water without air. A leak in the suction side of the pump can cause it to suck air, so check the joints for leaks using soapy water. If the well is gaseous, consult the factory about installing a sleeve in the well. Additionally, intermittent over-pumping of the well, where water is drawn down below the foot valve, can cause air spurts; lower the foot valve if possible, or restrict the pump discharge.
  • H
    Hannah PaulNov 14, 2025
    Why does my Simer 3325E Water Pump deliver water but not shut off?
    • J
      jamesgallagherNov 14, 2025
      If your Simer Water Pump delivers water but doesn't shut off or cycles too frequently, there could be several reasons. The pressure switch might be out of adjustment or its contacts could be welded together; in this case, disconnect the power and adjust or replace the pressure switch. Sometimes, faucets being left open can cause this issue, so ensure all faucets are closed. A clogged venturi, nozzle, or impeller can also prevent the pump from shutting off, so clean these components. If you have a standard pressure tank, it might be waterlogged and lack an air cushion; drain the tank to the air volume control port, check the AVC for defects, and inspect all connections for air leaks. Additionally, pipes or the foot valve might be leaking, so check these connections and replace the foot valv...
  • M
    millerdawnDec 1, 2025
    What to do if my Simer Water Pump motor runs but no water is delivered?
    • V
      Victoria GlassDec 1, 2025
      If your Simer Water Pump motor runs but no water is delivered, several issues could be the cause. In a new installation, the pump might not have picked up prime due to improper priming, air leaks, or a leaking foot valve or check valve. Re-prime according to instructions, check all connections with soapy water, and replace the foot valve or check valve. If the installation is already in use, the pump might have lost prime due to air leaks or the water level being below the suction pipe inlet. Check all connections and lower the suction line into the water to re-prime. Also, the foot valve or strainer could be plugged, so clean them. The ejector or impeller might also be plugged, requiring cleaning. A stuck check valve or foot valve would need replacement. Frozen pipes can also prevent wate...

Simer 3325E Specifications

General IconGeneral
Maximum head25 ft
Horsepower1/3 HP
Voltage115 V
Power cord length10 ft
Discharge size1.25 in
Switch typeVertical Float
Maximum solid handling size0.125 in
Inlet/Outlet Size1.25 in