EasyManua.ls Logo

Simer 3307P - User Manual

Simer 3307P
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OWNER’S MANUAL
Convertible Deep Well JetPumps
NOTICE D’UTILISATION
Pompe à éjecteur transformables
pour puits profonds
MANUAL DEL USUARIO
Bombas convertibles de chorro
para pozos profundos
2760 0197
© 2011 SIM918 (4/20/11)
3325E, 3327E
1543 0311
3305P, 3307P, 3310P
Installation/Operation/Parts
For further operating, installation, or
maintenance assistance:
Call 1-800-468-7867
English. . . . . . . . . . . Pages 2-16
Installation/Fonctionnement/Pièces
Pour plus de renseignements
concernant l’utilisation,
l’installation ou l’entretien,
Composer le 1 (800) 468-7867
Français. . . . . . . . . Pages 17-31
Instalación/Operación/Piezas
Para mayor información sobre el
funcionamiento, instalación o
mantenimiento de la bomba:
Llame al 1-800-468-7867
Español . . . . . . . Paginas 32-48
293 Wright Street, Delavan, WI 53115
Phone: 1-800-468-7867
Fax: 1-800-390-5351
Web Site: SimerPump.com

Questions and Answers

  • A
    aaron02Jul 30, 2025
    What to do if my Simer 3307P Water Pump motor will not run?
    • D
      Dr. Kellie KelleyJul 31, 2025
      If your Simer Water Pump motor isn't running, several factors could be at play. First, ensure the disconnect switch is turned on. If it is on, check the fuse and replace it if it's blown, or reset the circuit breaker if it has tripped. A defective starting switch could also be the culprit, in which case you should disconnect the power and replace the starting switch. Also, inspect the wires at the motor for looseness, disconnections, or incorrect wiring, referring to the wiring instructions. Remember to disconnect power before checking and tightening any wiring. If the pressure switch contacts are dirty, disconnect the power and file the contacts with an emery board or nail file.
  • L
    Luke CruzAug 9, 2025
    What to do if Simer Water Pump motor runs hot?
    • L
      Laura GrayAug 9, 2025
      If your Simer Water Pump motor runs hot and the overload kicks off, it could be due to incorrect wiring. Refer to the wiring instructions to ensure proper setup. Additionally, low voltage can cause the motor to overheat. Check with your power company and consider installing heavier wiring if the current wire size is too small, consulting the Electrical/Wiring Chart for guidance.
  • S
    Sarah GreenAug 14, 2025
    Why is my Simer 3307P Water Pump not delivering water to full capacity?
    • V
      Virginia ThomasAug 14, 2025
      If your Simer Water Pump isn't delivering water to its full capacity, it could be due to a few reasons. The water level in the well might be lower than estimated, potentially requiring a new nozzle and venturi combination. If you're using steel piping, it might be corroded or limed, causing excess friction; consider replacing it with plastic pipe where possible, or with new steel pipe. Also, the piping might be too small in size, so consider using larger piping.
  • K
    Kenneth FergusonAug 25, 2025
    Why is air spurting from the faucets when I use my Simer 3307P Water Pump?
    • D
      Derrick LambertAug 25, 2025
      If you're experiencing air spurts from your faucets when using your Simer Water Pump, it could be due to several reasons. The pump might be in the process of picking up prime; once it does, it should pump solid water without air. A leak in the suction side of the pump can cause it to suck air, so check the joints for leaks using soapy water. If the well is gaseous, consult the factory about installing a sleeve in the well. Additionally, intermittent over-pumping of the well, where water is drawn down below the foot valve, can cause air spurts; lower the foot valve if possible, or restrict the pump discharge.
  • A
    Amy ConleyNov 3, 2025
    Why does my Simer 3307P Water Pump deliver water but not shut off?
    • J
      joy91Nov 3, 2025
      If your Simer Water Pump delivers water but doesn't shut off or cycles too frequently, there could be several reasons. The pressure switch might be out of adjustment or its contacts could be welded together; in this case, disconnect the power and adjust or replace the pressure switch. Sometimes, faucets being left open can cause this issue, so ensure all faucets are closed. A clogged venturi, nozzle, or impeller can also prevent the pump from shutting off, so clean these components. If you have a standard pressure tank, it might be waterlogged and lack an air cushion; drain the tank to the air volume control port, check the AVC for defects, and inspect all connections for air leaks. Additionally, pipes or the foot valve might be leaking, so check these connections and replace the foot valv...
  • R
    Robert SchwartzNov 18, 2025
    What to do if my Simer Water Pump motor runs but no water is delivered?
    • J
      johnlewisNov 18, 2025
      If your Simer Water Pump motor runs but no water is delivered, several issues could be the cause. In a new installation, the pump might not have picked up prime due to improper priming, air leaks, or a leaking foot valve or check valve. Re-prime according to instructions, check all connections with soapy water, and replace the foot valve or check valve. If the installation is already in use, the pump might have lost prime due to air leaks or the water level being below the suction pipe inlet. Check all connections and lower the suction line into the water to re-prime. Also, the foot valve or strainer could be plugged, so clean them. The ejector or impeller might also be plugged, requiring cleaning. A stuck check valve or foot valve would need replacement. Frozen pipes can also prevent wate...

Summary

Convertible Deep Well Jet Pumps

Product Identification and Contact Information

Displays product models, company address, phone, and website.

Safety Instructions

General, Electrical, and Specific Safety Warnings

Covers hazardous voltages, motor heat, freezing, and specific warnings.

Warranty Information

Limited Warranty, Exclusions, and Terms

Details warranty period, what's covered, exclusions, and general terms.

Replacing an Existing Pump

Deep Well Pump Replacement Guide

Instructions for removing old deep well pumps and installing new ones.

Shallow Well Pump Replacement Guide

Instructions for removing old shallow well pumps and installing new ones.

Shallow Well Installation Guide

Well Point Installation Procedure

Details on installing driven points for shallow well jet pumps.

Cased Well Installation Procedure

Details on installing in 2" or larger cased wells for shallow jet pumps.

Shallow Well Installation Guide

Surface Water Installation Procedure

Steps for installing shallow well pumps for surface water sources.

Deep Well Installation Guide

4 Or Larger Deep Well Installation

Instructions for installing 4" or larger deep well jet pumps.

2 Single Pipe Deep Well Installation

Instructions for installing 2" single pipe deep well jet pumps.

Discharge Pipe and Pressure Tank Connections

Pre-Charge Tank Connection Setup

Guide for connecting pre-charged pressure tanks to the pump.

Standard Tank Connection Setup

Guide for connecting standard pressure tanks to the pump.

Electrical Connections and Wiring

Motor Switch Settings and Voltage Selection

How to set motor voltage and switch settings for proper operation.

Power Supply Connections and Grounding

Details on connecting power leads and ground wire safely.

Electrical Connections and Wiring

Wiring Connections and Fuse Sizes

Recommended wire sizes, fuse ratings, and connection procedures.

Deep Well Pump Startup Procedure

Priming and Initial Operation Steps

Step-by-step guide to fill, prime, and start a deep well jet pump.

Shallow Well Pump Startup Procedure

Priming and Initial Operation Steps

Step-by-step guide to fill and start a shallow well jet pump.

Troubleshooting Common Pump Issues

Symptom-Based Problem Diagnosis and Solutions

Guide to identify and fix problems like motor not running or no water delivery.

Repair Parts Identification

Cast Iron Model Parts List

Identifies specific parts for Cast Iron models 3325E and 3327E.

Corrosion Resistant Model Parts List

Identifies specific parts for Corrosion Resistant models 3305P, 3307P, 3310P.

Repair Parts Identification

Shallow Well Ejector Kit FP4855 Parts

Parts breakdown for the Shallow Well Kit FP4855.

Shallow Well Ejector Kit FP4875 Parts

Parts breakdown for the Shallow Well Kit FP4875.

Repair Parts Identification

Deep Well Ejector Kit FP4800 Parts

Parts and combinations for the Deep Well Kit FP4800.

2 Single Pipe Deep Well Ejector Kit FP4840 Parts

Parts and combinations for the 2" Single Pipe Deep Well Kit FP4840.

Simer 3307P Specifications

General IconGeneral
Maximum flow rate3300 GPH
Voltage115V
Max Flow Rate3300 GPH
Voltage/Frequency115V/60Hz
Housing MaterialThermoplastic
Impeller MaterialThermoplastic
Horsepower0.33 HP
Discharge size1.25 inches
Power cord length10 ft
Power0.33 HP
Inlet/Outlet Size1.25 inches
Cord Length10 ft

Related product manuals