Maintenance
After
replacing
either
or
both
rectifiers,
test
the
accuracy
of
A.C.
voltage
indications.
If
necessary,
recalibrate
the
circuit
by
adjusting
rheostats
R-28
and
R-31
as
follows:
1.
Set
the
function
switch
at
A.C.
and
the
range
switch
at
250
V.
2.
Connect
the
red
test
lead
in
the
+
jack
and
the
black
test
lead
in
the
COMMON
-
jack.
3.
From
a
standard
voltage
source,
apply
250
volts
A.C.
to
the
red
and
black
test
lead.
Adjust
rheostat
R-31
(which
is
next
to
the
+
meter
stud
on
the
printed
circuit
board)
so
the
meter
reads
full
scale.
Turn
power
off.
4.
Set
the
range
switch
to
2.5
V.
Apply
29
ое
to
the
red
and
black
test
leads.
Adjust
rheostat
R-28
(which
is
next
to
R-31)
so
the
meter
reads
full
scale.
Turn
power
off.
If
no
standard
voltage
supply
is
available
for
the
above
procedure,
return
your
Model
270
Series
2
to
the
Simpson
Electric
Company
or
an
Authorized
Warranty
Repair
Station
for
calibration.
RESISTOR
REPLACEMENT
Most
of
the
resistors
for
the
Simpson
Model
270
Series
2
are
on
the
rear
of
the
printed
circuit.
This
makes
them
easily
accessible
for
trouble-shooting
and
repair.
When
it
is
necessary
to
replace
any
of
the
resistors
in
the
circuit,
first
obtain
an
exact
equivalent
resistor.
The
best
way
to
do
this
is
to
order
the
resistor
or
resistors
directly
30

Related product manuals