8
1.8 Technical Data
Table 1-1 lists the technical data for the 260-8.
TABLE 1-1. Technical Data
1. DC VOLTS:
Ranges: 0-1-2.5-10-25-50-250-500-1000V
Sensitivity: 20,000 ohms per volt
2. DC MILLIVOLTS:
Range: 0-250mV
Sensitivity: 20,000 ohms per volt
3. AC VOLTS:
Ranges: 0-2.5-10-25-50-250-500-1000V
Sensitivity: 5,000 ohms per volt
4. OUTPUT VOLTAGE (AC):
Ranges: 0-2.5-10-25-50-250 (limited to 350 VDC)
5. DC MICROAMPERES:
Range: 0-50μA
Voltage Drop: 250mV
6. DC MILLIAMPERES:
Ranges: 0-1-10-100-500 mA
Voltage Drop (Approx.): 250 mV, 255 mV, 300 mV, 500 mV
7. DC AMPERES:
Range: 0-10A
Voltage Drop (Approx.): 255 mV
NOTE: The 10A range is not internally fused.
8.
ECNATSISE1RX0R01X0R00,01XR
egnaVR000,2-V0000,002-V0M02-0
gnidaeRretneVC2V1002V1000,021
nepOlanimoN
egatloVtiucriC
V5.1V5.1V9
tr
ohSlanimoN
tnerruCtiucriC
Am52A1m52.A1 μ57
9. * ACCURACY:
DC Voltage Ranges: 2% of Full Scale
DC Current:
0-50 μA Range: 1.5% of Full Scale
Other Ranges: 2% of Full Scale
**AC Voltage Ranges: 3% of Full Scale
Frequency Response: Referenced to 100 Hz (Figures 4-4 and 4-9)
Resistance Ranges:
R X 1: 2.5° of Arc
R X 100: 2° of Arc
R X 10,000: 2° of Arc
* Accuracies specified are for the 260 in a horizontal position.