52
Installation and Maintenance
Step
Procedure
10.Remove condenser assy, evaporator assy
Lift up, remove the condenserassy and evaporator assy.
11.Remove Fan Motor and Centrifugal Fan Blade
Remove Screws xing the bar clasp, remove the fan
motor and centrifugal fan blade.
12.Remove Centrifugal Fan Blade
a
Remove screws xing the centrifugal fan; Pull out in the
direction of the arrow, remove the centrifugal fan.
Evaporator assy
Condenser assy
Rivet Jiont Nut
Bar Clasp
Fan Motor(outside)
Centrifugal fan
blade(inside)
screws
screws