Technical Information
Service Manual
●
 
Indoor Unit
1.Basic function of system
(1)Cooling mode
(1) 
 
Under 
 
this 
 
mode, 
 
fan 
 
and 
 
swing 
 
operates 
 
at 
 
setting 
 
status.
O
Temperature setting range is 16~30
 
C.
(2) 
 
During 
 
malfunction 
 
of 
 
outdoor 
 
unit 
 
or 
 
the 
 
unit 
 
is 
 
stopped
 
because of protection, indoor unit keeps original operation status.
(2)Drying mode
(1) 
 
Under 
 
this 
 
mode, 
 
fan 
 
operates 
 
at 
 
low 
 
speed 
 
and 
 
swing
O
operates at setting status. Temperature setting range is 16~30
 
C.
(2) 
 
During 
 
malfunction 
 
of 
 
outdoor 
 
unit 
 
or 
 
the 
 
unit 
 
is 
 
stopped
 
because of protection, indoor unit keeps original operation status.
(3) Protection status is same as that under cooling mode.
(4) Sleep function is not available for drying mode.
(3)Heating mode
O
(1) Under this mode, Temperature setting range is 16~30
 
C.
(2) Working condition and process for heating mode:
When turn on the unit under heating mode, indoor unit enters into
 
cold 
 
air 
 
prevention 
 
status. 
 
When 
 
the 
 
unit 
 
is 
 
stopped 
 
or 
 
at 
 
OFF
 
status, 
 
and 
 
indoor 
 
unit 
 
has 
 
been 
 
started 
 
up 
 
just 
 
now, 
 
the 
 
unit
 
enters into residual heat-blowing status.
(4)Working method for AUTO mode:
1.Working condition and process for AUTO mode:
O
a.Under AUTO 
 
mode, 
 
standard 
 
heating 
 
Tpreset=20
 
C 
 
and
O
standard 
 
cooling 
 
Tpreset=25
 
C. 
 
The 
 
unit 
 
will 
 
switch 
 
mode
 
automatically according to ambient temperature.
2.Protection function
a. 
 
During 
 
cooling 
 
operation, 
 
protection 
 
function 
 
is 
 
same 
 
as 
 
that
 
under cooling mode.
b. 
 
During 
 
heating 
 
operation, 
 
protection 
 
function 
 
is 
 
same 
 
as 
 
that
 
under heating mode.
3. Display: Set temperature is the set value under each condition.
 
Ambient 
 
temperature 
 
is 
 
(Tamb.-Tcompensation) 
 
for 
 
heat 
 
pump
 
unit and Tamb. for cooling only unit.
4. 
 
If 
 
theres 
 
I 
 
feel 
 
function, Tcompensation 
 
is 
 
0. 
 
Others 
 
are 
 
same
 
as above.
(5)Fan mode
Under 
 
this 
 
mode, 
 
indoor 
 
fan 
 
operate s 
 
at 
 
set 
 
fan 
 
speed.
 
Compressor, 
 
outdoor 
 
fan, 
 
4-way 
 
valve 
 
and 
 
electric 
 
heating 
 
tube
 
stop operation. Indoor fan can select to operate at high, medium,
O
low or auto fan speed. Temperature setting range is 16~30
 
C.
2. Other control
(1) Buzzer
Upon 
 
energization 
 
or 
 
availably 
 
operating 
 
the 
 
unit 
 
or 
 
remote
 
controller, the buzzer will give out a beep.
(2) Auto button
If 
 
press 
 
this 
 
auto 
 
button 
 
when 
 
turning 
 
off 
 
the 
 
unit, 
 
the 
 
complete
unit 
 
will 
 
operate 
 
at 
 
auto 
 
mode. 
 
Indoor 
 
fan 
 
operates 
 
at 
 
auto 
 
fan
18
speed and swing function is turned on. Press this auto button at 
ON status to turn off the unit.
(3) Auto fan
Heating mode: During auto heating mode or normal heating ode, 
auto fan speed will adjust the fan speed automatically according 
to ambient temperature and set temperature.
(4) Sleep
After setting sleep function for a period of time, system will adjust 
set temperature automatically.
(5) Timer function:
General timer and clock timer functions are compatible by 
equipping remote controller with different functions.
(6) Memory function
memorize compensation temperature, off-peak energization value.
Memory content: mode, up&down swing, light, set temperature, 
set fan speed, general timer (clock timer cant be memorized).
After power recovery, the unit will be turned on automatically 
according to memory content.
(7) Health function
During operation of indoor fan, set health function by remote 
controller. Turn off the unit will also turn off health function.
Turn on the unit by pressing auto button, and the health is 
defaulted ON.
(8)I feel control mode
After controller received I feel control signal and ambient 
temperature sent by remote controller, controller will work 
according to the ambient temperature sent by remote controller.
(9)Entry condition for compulsory defrosting function
When turn on the unit under heating ode and set temperature is 
16
O
C (or 16.5
O
C by remote controller), press “▲, ▼, ▲, ▼, ▲, ▼” 
button successively within 5s and then indoor unit will enter into 
compulsory defrosting setting status:
(1) If theres only indoor units controller, it enters into indoor normal 
defrosting mode.
(2) If theres indoor units controller and outdoor units controller, 
indoor unit will send compulsory defrosting mode signal to outdoor 
unit and then outdoor unit will operate under normal defrosting 
mode. After indoor unit received the signal that outdoor unit has 
entered into defrosting status, indoor unit will cancel to send 
compulsory mode to outdoor unit. If outdoor unit hasnt received 
feedback signal from outdoor unit after 3min, indoor unit will also 
cancel to send compulsory defrosting signal.
(10)Refrigerant recovery function: 
Enter into Freon recovery mode actively: Within 5min after 
energization, turn on the unit at 16
O
C under cooling mode, and 
press light button for 3 times within 3s to enter into Freon recovery 
mode. Fo is displayed and Freon recovery mode will be sent to 
outdoor unit.
(11)Ambient temperature display control mode
1. When user set the remote controller to display set temperature 
(corresponding remote control code: 01), current set temperature 
6.2 Brief Description of Models and Functions