39
Installation and Maintenance
Service Manual
NO. Items to be checked Possible malfunction
1
Has the unit been installed 
rmly?
The unit may drop, shake or 
emit noise.
2
Have you done the 
refrigerant leakage test?
It may cause insufcient 
cooling (heating) capacity.
3
Is heat insulation of pipeline 
sufcient?
It may cause condensation 
and water dripping.
4 Is water drained well?
It may cause condensation 
and water dripping.
5
Is the voltage of power 
supply according to the 
voltage marked on the 
nameplate?
It may cause malfunction or 
damage the parts.
6
Is electric wiring and pipeline 
installed correctly?
It may cause malfunction or 
damage the parts.
7
Is the unit grounded 
securely?
It may cause electric 
leakage.
8
Does the power cord follow 
the specication?
It may cause malfunction or 
damage the parts.
9
Is there any obstruction in 
air inlet and air outlet?
It may cause insufcient 
cooling (heating) capacity.
10
The dust and sundries 
caused during installation 
are removed?
It may cause malfunction or 
damaging the parts.
11
The gas valve and liquid 
valve of connection pipe are 
open completely?
It may cause insufcient 
cooling (heating) capacity.
12
Is the inlet and outlet of 
piping hole been covered?
It may cause insufcient 
cooling(heating) capacity or 
waster eletricity.
1. Check after Installation
Check according to the following requirement after finishing 
installation.
2. Test Operation
(1) Preparation of test operation
● The client approves the air conditioner installation.
● Specify the important notes for air conditioner to the client.
(2) Method of test operation
● Put through  the  power,  press  ON/OFF  button  on the remote 
controller to start operation.
● Press  MODE  button  to select AUTO,  COOL,  DRY,  FAN  and 
HEAT to check whether the operation is normal or not.
●  If  the  ambient  temperature  is  lower  than  16
℃
, the air 
conditioner cant start cooling.
8.8 Check after Installation and Test operation