Maintenance and Inspection
Please carry out regular maintenance and inspection on the drive and motor for safe use.
Notes for maintenance and inspection
1) The operator should first cut off the power supply. Do not approach the motor and the machine
it drives when wrong actions occur during power-on.
2) For a short period of time after the power supply is cut off, the internal circuit still maintains a
high voltage charging state. Before inspection, the power supply must be cut off; wait for 10
minutes, and make sure that the charging light is completely off.
3) If it is necessary to test the insulation resistance of the drive, all connections to the drive must
be cut off. Insulation resistance test on the drive connected with wires or a motor will damage
the device.
4) Do not use gasoline, diluents, acidic or alkaline detergents to clean the device, otherwise
discoloration or damage to the case may occur.
Inspection items and frequencies
Normal use conditions
Daily inspections and regular inspections shall be carried out according to the following list
below.
Confirm the use environment (temperature and humidity,
dust, foreign matters)
Check for any abnormal vibration or sounds
Check whether the power supply voltage is in the normal
range
Check for peculiar odors
Check for fiber adhesion at the vents
Check whether connections are clean and tight
Check for wire damage
Check whether any connection with the device is loose or
eccentricity occurs
Check whether any foreign matter has entered the
mechanical transmission part
Check whether any fastening part is loose
Check for signs of overheating
Check whether there is any oil leakage in the transmission
mechanism and whether the shaft extension of the motor
has been polluted.
Check whether the terminals are intact
Check whether any connection between wires and the
drive is loose
The environmental conditions are as follows: the annual average temperature is 30 ℃,