Reply: MILEAGE RESET OK
Sample: 1420000M1000
Reply: SET OK, CURRENT: 1000
Red the current Mileage
Command: 143+password
Sample: 1430000
Reply: CURRENT TOTAL MILEAGE:XX.
XX is the mileage, the unit is meter.
11. Shock Alarm (send SMS alarm to the first number)
Open Shock Alarm: 181+password+T
Sample: 1810000T10
Reply: SET OK
The T meaning shocking time, the unit is second,
It from 0 to 120 senconds.
Close Shock Alarm: 180+password
Sample: 1800000
Reply: SET OK
12. Low battery alarm (send SMS to first number)
When the battery is low, the tracker will send the Low Power Alarm SMS to thfirst number
When the battery is Full, Bat:5, means 100%; Bat:4 means 80%, Bat:3 means 60%, Bat:2 means 40%, Bat:1 means
20%. When the Bat is 1, it will send low battery alarm.
13. Call mode
Call mode on:
Command: 150+password
Sample: 1500000
Reply: SET OK
Call mode off
Command: 151+password
Sample: 1510000
Reply: SET OK
When the call mode on, the alarms will call and send SMS to the control number,
When the call mode off, only send SMS.
14. Sleep mode
Open Sleep mode
Command: SLEEP0000 1
Reply: SET OK
Close Sleep mode
Command: SLEEP0000 0