Page 5
A) Connect water to the Machine 1 through the supplied water filter.
Open the tap fully.
B) Connect electricity to machine 2 and turn on the power at the
power point.
C) Check that the earth leakage switch(this switch provides protection
to the operator and in case of variations in current
) 15 is turned
on.
D) To turn the machine on. Use the “ON/OFF” button 3 on the
control panel 4 Press for 3 seconds.
E) Water tank will fill w ith water 14.
F) When the water tank is full the w ater will stop automatically and
the recirculating pump starts.
G) The water temperature will automatically appear on the control
panel display 5 .
H) Set the controls to the required cooling or h eating temperature in
the models ending with N”. (Difference between cut in and out
temperature is 2 degrees.) To set the required temperature. Press
“SET” 7 , the temperature display 5 will flash press CE” 8 to
clear previous setting, enter the temperature that you require by
using the numerical key pad 11 (minimum temperature 2 degrees
and maximum 32 degrees for the heater units), leave for 30 seconds
or press “SET . and the figures will stop flashing. The water cooler
will now either cool or heat up the water.
I) The compressor will start if the w ater is warmer then the set
required temperature and the ice cycle symbol light 9 on the
control unit will come on. For the heater models if the water is
cooler than the set temperature the element will start heating the
water and the sun symbols 10 will come on.
J) When the required temperature is reached the compressor will stop
and the ice cycle symbol light w ill go off. For the heater models the
element will sw itch off and the sun symbol will go out.
K) To enter the required quantity (litres) 18 of water to be deposited
press “CE” to clear the previous setting and then enter the required
amount using the key pad. To enter decimal litres press “.” 20 and
then the decimal amount required.