Interface with Dataloggers and Vibration Systems
SKF Copperhead Transmitter Unit CMPT CTU9-24
Instruction Manual
Interface with Dataloggers and Vibration Systems
9
The CMPT CTU is equipped with a front panel BNC connector to enable connection to
the buffered output signal of the connected accelerometer sensor. This enables use of
the SKF MarlinVIBPAK and SKF Microlog dataloggers, or an equivalent vibration
spectrum datalogger to safely and easily connect to the sensor without interference.
The BNC connector can be switched to “TEMP” to enable measurement of the sensor
temperature signal (optional).
The CTU also has screw terminals (numbers 9 and 10) for connection of the buffered
output signal to other vibration monitoring devices.
The processed Acceleration Enveloping, Acceleration and Velocity output signals from
the CTU will likely be different than the values obtained directly with the SKF Microlog
datalogger owing to slight differences in the way the signal is processed and how the
frequency point in the datalogger is configured.