5.8 Power level selection
When heating bearings with an induction heater, most of the heat will be generated in the
inner bearing race. The heat will then be transferred through the bearing. It is therefore
important that bearings with reduced internal clearance are heated slowly. Slow heating
ensures that the bearing expands evenly, thereby preventing damage to the bearing.
The shape, weight, size, and internal clearances all affect the amount of time required to
heat a bearing. The large variety of bearing types precludes the possibility of providing a
specific power level setting for each type. Instead, the following guidelines are provided:
“For sensitive bearings (including bearings with C1 or C2 internal clearance) or
bearings with brass cages, preferably use 50% power.
“When using the small yoke, never exceed 50% power.
6. Safety features
The TIH 100m is equipped with the following safety features:
Automatic overheating protection
Automatic current control
“Over-current circuit breaker.
“In the TEMP MODE the heater will switch off if the temperature probe does not
register a temperature increase of 1 °C (1.8 °F) every 15 seconds (0.25 minute).
To increase the interval to 30 seconds (0.50 minute), press MODE and DOWN at the
same time.
English

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF TIH 100m and is the answer not in the manual?

SKF TIH 100m Specifications

General IconGeneral
BrandSKF
ModelTIH 100m
CategoryElectric Heater
LanguageEnglish

Related product manuals