7. Troubleshooting
A system fault will be indicated by an acoustic signal and one of the following fault codes
on the remote control display:
Display Fault Action
E03 E Overheated coil Wait until the inductive coil cools.
Switch the heater OFF and then
back ON
E05 E Temperature increase of less than
1 °C (1.8 °F) every 15 seconds
(or 1 °C (1.8 °F) every 30 seconds)
Check the temperature probe
connection. If the connection is OK,
select the 30 second interval as
described in section 6 or operate
the heater in TIME MODE
E06 E Temperature probe not connected
(or defective) or excessive
temperature drop
Check the temperature probe
E10 E Electronics communication problem Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair
E11 E Electronics communication problem Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair
E12E Electronics communication problem Switch the heater OFF and then
back ON. If problem remains return
the TIH to SKF for repair