Instructions for use
SKF TKST 11

Questions and Answers

Summary

Safety Precautions

Important Safety Guidance

Covers critical warnings, warranty voidance, proper disposal, and operational notes for safe use.

EU and UK Declarations

Declarations Overview

Presents the EU and UK Declarations of Conformity for the TKST 11 product.

Operating Instructions

Product Introduction and Warnings

Details the stethoscope components, includes essential warnings, and lists package contents.

Product Details and Usage

Stethoscope Diagram and Wireframe

Illustrates the SKF TKST 11 stethoscope, its parts, and display elements.

Listening and Muting Examples

Provides visual examples of the stethoscope in use, showing listening and muted states.

Technical Specifications

SKF TKST 11 Technical Data

Lists detailed technical specifications including frequency range, temperature, battery, and weight.

Operational Guide

Getting Started with the Stethoscope

Step-by-step guide for inserting batteries and setting up the stethoscope and headset.

General Usage Instructions

Explains how to operate the stethoscope, adjust volume, mute, and turn it off.

Support and Maintenance

Troubleshooting Common Issues

Provides solutions for common problems like a dirty display or short operating time.

Spare Parts and Accessories

Lists available spare parts and accessories for the SKF TKST 11 stethoscope.

Summary

Safety Precautions

Important Safety Guidance

Covers critical warnings, warranty voidance, proper disposal, and operational notes for safe use.

EU and UK Declarations

Declarations Overview

Presents the EU and UK Declarations of Conformity for the TKST 11 product.

Operating Instructions

Product Introduction and Warnings

Details the stethoscope components, includes essential warnings, and lists package contents.

Product Details and Usage

Stethoscope Diagram and Wireframe

Illustrates the SKF TKST 11 stethoscope, its parts, and display elements.

Listening and Muting Examples

Provides visual examples of the stethoscope in use, showing listening and muted states.

Technical Specifications

SKF TKST 11 Technical Data

Lists detailed technical specifications including frequency range, temperature, battery, and weight.

Operational Guide

Getting Started with the Stethoscope

Step-by-step guide for inserting batteries and setting up the stethoscope and headset.

General Usage Instructions

Explains how to operate the stethoscope, adjust volume, mute, and turn it off.

Support and Maintenance

Troubleshooting Common Issues

Provides solutions for common problems like a dirty display or short operating time.

Spare Parts and Accessories

Lists available spare parts and accessories for the SKF TKST 11 stethoscope.

Overview

The SKF TKST 11 is a robust and versatile electronic stethoscope designed for inspecting moving, rotating, and vibrating objects. It serves as a crucial tool for maintenance professionals, enabling them to listen to machinery sounds and identify potential issues before they escalate into costly failures. The device is engineered for ease of use, providing clear auditory feedback to help diagnose problems in various industrial settings.

Function Description

At its core, the SKF TKST 11 functions as an acoustic diagnostic instrument. It amplifies the sounds generated by machinery, allowing users to detect subtle changes in noise patterns that may indicate wear, damage, or misalignment. The device converts mechanical vibrations into audible signals, which are then transmitted to the user via a headset. This allows for a detailed assessment of the internal condition of components such as bearings, gears, pumps, and motors. By isolating and amplifying these sounds, the stethoscope helps pinpoint the exact location and nature of a problem, facilitating proactive maintenance and preventing unexpected downtime.

The stethoscope is equipped with a sensitive probe that makes direct contact with the machine surface. This probe picks up the vibrations, which are then processed by the device's internal electronics. The amplified sound is delivered to the user through a comfortable headset, ensuring that external noise interference is minimized, and the machinery sounds are clearly distinguishable. The device's ability to provide clear, high-fidelity audio is essential for accurate diagnosis, allowing users to differentiate between normal operating sounds and those indicative of a fault.

Usage Features

The SKF TKST 11 is designed with user convenience and operational efficiency in mind. It features a straightforward interface that allows for quick setup and intuitive operation.

  • Getting Started: To begin using the device, users first need to install two AA batteries into the battery compartment, ensuring correct polarity. Once the batteries are in place and the compartment is secured, the chosen probe tip (either short or long) is screwed onto the device. The short probe is ideal for easily accessible machinery, while the long probe is suited for reaching areas with limited access. The headset cable is then plugged into the device, with the 90-degree angle jack plug side connecting to the headset outlet and the other end securing to the device with a thumb screw. The stethoscope is powered on by pressing the ON/OFF button for two seconds.

  • Listening and Diagnosis: Once powered on, the device is ready for use. The user gently presses the tip of the probe against a non-movable area of the running machine. The device's display shows the volume level, both numerically and graphically, along with the battery status. The volume can be easily adjusted using the direct access buttons: the left button decreases the volume, and the right button increases it. This allows the user to fine-tune the audio to clearly hear the machinery sounds, adapting to different noise environments and the specific characteristics of the sounds being investigated.

  • Mute Function: A central button on the device serves as a mute/unmute function. This feature is particularly useful for temporarily silencing the audio without having to adjust the volume settings, allowing the user to pause listening or communicate without removing the headset.

  • Probe Selection: The inclusion of two different probe lengths (short and long) enhances the versatility of the TKST 11. The short probe is practical for general use and easily accessible components, offering good maneuverability. The long probe extends the reach of the stethoscope, making it possible to inspect components in confined spaces or areas that are otherwise difficult to access safely. This flexibility ensures that the device can be effectively used across a wide range of machinery types and configurations.

  • Automatic Shut-off: To conserve battery life, the SKF TKST 11 is equipped with an auto-off function. If left untouched for 10 minutes, the stethoscope will automatically power down. This feature prevents unnecessary battery drain, ensuring the device is ready for use when needed. Users can also manually turn off the device by pressing the OFF button for two seconds.

  • External Jack Plug: The device includes an external jack plug, which allows for the connection of a recording device. While the recording device itself is not sold by SKF, this feature enables users to capture and store machinery sounds for later analysis, comparison, or documentation. This can be invaluable for trend monitoring, expert consultation, or training purposes.

Maintenance Features

Maintaining the SKF TKST 11 is straightforward, focusing on ensuring its longevity and consistent performance.

  • Cleaning: The display area of the device should be cleaned with a wet cotton swab, followed by a clean, dry cotton cloth to remove any water residue. It is important not to wash the display with excessive water or solvents, as this could damage the screen or internal components.

  • Battery Replacement: If the screen freezes or the operating time becomes too short, the first step in troubleshooting is often related to the batteries. Users should remove the batteries and wait for one minute before reinserting them. If the issue persists or the battery low signal appears, the batteries should be replaced with new AA alkaline batteries. The device is designed for a minimum of 30 hours of continuous use on a fresh set of batteries.

  • Storage: Proper storage is crucial for the device's lifespan. The stethoscope should not be stored in environments with very high or very low temperatures. Extreme temperatures can affect battery performance and the integrity of the electronic components. The device comes with a dedicated toolcase with an inlay, which provides protection during transport and storage, safeguarding it from rough handling or heavy impacts.

  • Repair and Warranty: The SKF TKST 11 is a precision instrument, and any repair work should only be performed by an authorized SKF repair shop. Opening the housing of the instrument by unauthorized personnel will void the warranty and may lead to hazardous mishandling. This ensures that the device is repaired correctly and maintains its operational integrity and safety standards.

  • Disposal: The electronic components within the device contain environmentally harmful substances. Therefore, the SKF TKST 11 must be disposed of in accordance with the environmental regulations of the country of use. This commitment to responsible disposal underscores SKF's dedication to environmental stewardship.

In summary, the SKF TKST 11 is an indispensable tool for proactive maintenance, offering a user-friendly design, versatile functionality, and clear auditory feedback to help professionals identify and address machinery issues efficiently. Its robust construction and thoughtful features make it a reliable partner in industrial diagnostics.

SKF TKST 11 Specifications

General IconGeneral
DisplayLCD
Protection classIP54
Measurement Range30 to 300 000 flashes per minute (FPM) or revolutions per minute (RPM)
Resolution0.1 RPM (below 1, 000 RPM), 1 RPM (above 1, 000 RPM)
Flash Rate30 to 300 000 flashes per minute (FPM)
Operating Temperature0 to +50 °C
MaterialPlastic
Power Supply4 × AA batteries
Weight300 g (0.66 lb) including batteries