EasyManua.ls Logo

SKF Microlog GX Series User Manual

SKF Microlog GX Series
342 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SKF Microlog
®
GX Series
Data Collector/Analyzer
Supports the GX Series Microlog System CMXA 75
Firmware Version 4.05
User Manual Part No. 32298500-EN
Revision E
User Manual
Read this manual before using this product. Failure to follow the instructions
and safety precautions in this manual can result in serious injury, damage to the
product, or incorrect readings. Keep this manual in a safe location for future
reference.
Copyright 2016 by SKF USA Inc.
All rights reserved.
5271 Viewridge Court, San Diego, CA 92123-1841 USA
Telephone: (858) 496-3400, Fax: (858) 496-3531
Customer Service: 1-800-523-7514

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the SKF Microlog GX Series and is the answer not in the manual?

SKF Microlog GX Series Specifications

General IconGeneral
BrandSKF
ModelMicrolog GX Series
CategoryMeasuring Instruments
LanguageEnglish

Summary

Introduction to the SKF GX Series Microlog

Safety Messages

General safety warnings and precautions for handling the equipment.

Personnel Safety

Guidelines for personal safety while operating the Microlog device.

Hazardous Locations

Safety requirements for using the instrument in hazardous environments.

About This Manual

Overview of the manual's content and purpose.

How to Set Up Your GX Series Microlog

System Settings

Configuration of system preferences and operational settings for the Microlog.

Global Measurement Settings

Settings that apply to all Microlog measurements and data collection.

Sensor Setup

Configuration of sensor parameters and selection of appropriate sensors.

Troubleshooting

Guidance on resolving common operational issues and errors with the Microlog.

The ROUTE Module

How to Download and Upload ROUTEs and ROUTE Data with the GX Series Microlog

Procedures for transferring data between Microlog and host software.

How to Collect ROUTE Measurements

Step-by-step guide for performing data collection within a ROUTE.

Viewing Dynamic Measurement Data

Analysis of spectral data collected during ROUTE measurements.

How to Review Collected Data

Accessing and analyzing previously stored measurement data.

The Analyzer Module

How to Collect Standard Vibration Measurements

Procedures for performing standard vibration measurements using the Analyzer.

How to Save, View, and Delete Analyzer Measurement Results

Managing saved measurement data and setups.

How to Perform Multi-Channel Measurements

Performing measurements using multiple input channels simultaneously.

How to Perform a Bump Test

Identifying natural frequencies of a machine or structure using impact testing.

Machinery Balancing Module

How to Set Up the Microlog for a Single-Plane Procedure

Configuring parameters for single-plane balancing jobs.

Perform the Trial Run

Conducting the trial run to calibrate unbalance and calculate correction weights.

Two-Plane Balancing Procedure Overview

Overview of the procedure for balancing with two planes.

How to Perform a 1-2 Plane with Prognosis Procedure

Procedure for determining if single-plane balancing is sufficient.

Data Recorder Module

How to Perform a Data Recorder Measurement

Steps to initiate and perform data recording.

Recording the Measurement

The process of initiating, pausing, and saving recorded data.

How to Change the Measurement Setup before Performing the Measurement

Customizing recorder measurement settings before data acquisition.

Run Up / Coast Down Module

How to Set Up a RUCD Measurement

Setting up parameters for run up/coast down measurements.

Displaying Acquired Data

Options for analyzing recorded RUCD data.

Waterfall Plot Display

Visualizing data over time and speed changes using waterfall plots.

Frequency Response Function Module

How to Set Up an FRF Measurement

Steps for setting up the test apparatus and configuring FRF parameters.

Recording the Measurement

The process of collecting FRF data using the Microlog.

Field Calibration

Performing calibration checks using known masses.

Conformance Check Module

How to Transfer Test Templates to the Microlog GX

Procedures for transferring test templates from host computer to Microlog.

How to Set Up or Customize Conformance Test Templates

Using software to create or modify test templates.

Performing a Conformance Survey

Steps to conduct before-and-after conformance tests.

Spindle Test Module

How to Perform a Survey

Steps for conducting spindle condition surveys.

Imbalance Test Overview

Performing tests to determine imbalance conditions.

Bearing Condition test overview

Evaluating the condition of spindle bearings.

Nose Run-Out test overview

Measuring the run-out of the spindle nose.

Idler Sound Monitor Module

Hardware Setup

Instructions for assembling the Idler Sound Monitor kit components.

How to Set Up a Conveyor Idler Survey

Defining conveyor specifics and measurement settings for surveys.

How to Analyze Faulty Idler Rollers

Viewing measurement results to identify specific conveyor idler faults.

How to Delete Stored Survey Data Files on the Microlog

Freeing up memory by deleting stored data files.

Appendix A Non ROUTE

Non ROUTE Mode Operations

Overview of available measurement data collection options in Non ROUTE mode.

How to Collect Pre-set Non ROUTE Measurements

Performing standard measurements using pre-defined settings.

How to Collect “User” Defined Non ROUTE Data

Setting up new measurements with custom parameters.

How to Set Up Multi-Channel Measurements

Configuring and performing measurements using multiple channels.

Appendix B Field Upgrades and Accessories

Field Upgrades

List of available software and hardware upgrades.

Accessories

List of compatible accessories like sensors and cables.

Appendix C Using the Headphones and Strobe Light

How to Use the Headphones with the GX

Connecting and controlling headphones for audio output.

How to Use the Strobe Light with the GX

Connecting and using the strobe light for balancing and motion studies.

Appendix D Safety Instructions

Hazardous (Classified) Location Class I, Division 2, Groups A, B, C, and D

Safety instructions for Class I, Division 2 hazardous environments.

Safety Instructions (090-22861-1 Rev C)

Specific safety instructions for ATEX Zone 2 hazardous area installations.

Connecting an accelerometer to the instrument

Diagram showing accelerometer connection to CH1 and CH2 ports.

Glossary of Terms

Related product manuals