Machinery Balancing Module
How to Perform a Dynamic 2 Plane Procedure
Add a Trial Weight to Plane A
Typically, you add the trial weight to plane A and perform Plane
A’s trial run and then repeat the trial weight / run procedure for
plane B.
From the Initial Run screen, press an Enter button. The Balancer Trial Weight
TW A1 screen displays.
Figure 5 - 24.
Plane A’s Trial Weight Screen.
display plane B’s trial weight screen
If you wish to perform a trial run for Plane B first, press the Plane
B function button to display Plane B’s Trial Weight screen.
Stop the machine.
On the Microlog, enter the Trial Weight, Angle and Radius for the trial weight you
are attaching to Plane A.
The Rotor Mass field is used if you wish to have the Microlog
estimate the trial weight. Reference the How to Estimate Trial
Weights section below for detail.
Trial weights are typically attached at zero degrees (the trigger
reference).
Unless you wish the Microlog to estimate a trial weight, the
Radius entry is not necessary, so long as you position the trial,
correction, and trim weights at the same radius.
On the machine, carefully attach the precise weight at the precise angle and radius
specified. Balancing results depend greatly on the precision of your measurements
and actions.