Frequency Response Function Module
How to Set Up an FRF Measurement
Figure 8 - 2.
The FRF Menu Screen.
FRF menu options are:
RecallRecalls the setup screen for the last FRF measurement that was taken
(whether it was saved or not).
Modal 1kHz Initiates a measurement setup that can be used in conjunction with
modal analysis software to model the way the structure will react to forces applied to it.
ODS 1kHz Initiates a measurement setup that captures information about how a
machine moves when it is running. This information can be used in conjunction with
Operation Deflection Shape (ODS) analysis software.
New - Provides another way to set up a new “user defined” FRF measurement.
ReviewInitiates the FRF – Load Setup screen allowing you to review previously
saved FRF measurement data or saved FRF measurement setups.
Function Buttons
Function buttons at the bottom of the FRF screen include:
Help Displays the Microlog’s context sensitive help screen.
Setup Displays the measurement setup screen for the highlighted measurement type
(i.e., Recall, Modal 1kHz, ODS 1kHz, or New).
StartTake FRF data using the currently highlighted icon’s settings.
BackReturns you the Microlog’s Main Menu screen.
From the FRF menu, highlight the New icon and select the Setup button. The New
FRF measurement setup screen displays.
8 - 4 SKF Microlog - GX Series
User Manual