The ROUTE Module
How to Review Collected Data
How to Review Orbit Data
Orbit POINTs support the collection of two-channel data which is displayed as an orbit
in the review screen.
To review orbit data:
In the ROUTE hierarchy, use the left, right, up, and down arrows to highlight the
orbit POINT you would like to review and press the Review function button. The
Review Orbit screen displays.
Figure 3 - 16.
The Review Orbit Screen.
Use the left/right arrows to move the cursor between individual data points on the
orbit display.
The Review screen’s orbit display operations are similar to Route
mode operations, except the Retake and Notes function buttons
are unavailable, and the review screen includes an option to
Delete the stored measurement. Refer to the ROUTE Data
Collection section’s Viewing Dynamic Measurement Data
section for more information on orbit display analysis features.
If you would like to delete the stored measurement, press the Delete function
button. A confirmation message appears. Press Yes to remove the measurement
or No to retain it.
After reviewing the measurement’s data, press either an Enter button or the Back
function button to return to the ROUTE hierarchy.
3 - 30 SKF Microlog - GX Series
User Manual