Run Up / Coast Down Module
Recording the Measurement
Recording the Measurement
• From the Setup screen, press the Start function button to enter the RUCD’s
Taking Data mode.
If you highlight a measurement’s icon and press the Enter (Fire)
button instead of the Start function button, you will display the
measurement’s setup screen, not start the measurement.
Figure 7 - 4.
The RUCD Taking Data Screen.
In Taking Data mode, the RUCD – Taking Data screen shows data collection status.
State – (Armed or Acquiring or Error)
Armed – Indicates the machine speed has not reached the preset
measurement “start” speed, data collection is not occurring.
You may press the display’s Start function button at any time to
manually start data acquisition.
Acquiring – Indicates the machine speed has reached the measurement “start”
speed and data is being recorded.
During data acquisition, the Start function button changes to a
Stop function button. Press this Stop function button to
manually stop data acquisition at any time.
Error - Clipped message- In the message area, if a sensor’s Input Range
setting (full scale setting) is too small to accommodate the signal’s amplitude, a
Signal Clipped message displays. In this case, press the Back function button
to return to the Setup screen and increase the Input Range setting.
7 - 6 SKF Microlog - GX Series
User Manual