EasyManua.ls Logo

SKF Microlog GX Series - How to Set up a Cross Channel Phase Measurements

SKF Microlog GX Series
342 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Non ROUTE
How to Set Up a Cross Channel Phase Measurements
How to Set Up a Cross Channel Phase Measurements
Overview
A cross-channel phase measurement displays the spectra for input channels 1 & 2, and
the relative phase angle between the two input channels. Note that the phase
difference between the two inputs is measured. This is known as relative phase.
Spectra for both input channels are stored, and the relative phase between the two
channels is displayed as a table of magnitude/phase pairs of up to 8 orders of running
speed.
Measurement Setup
To set up and collect a Non ROUTE cross-channel phase measurement:
From the main screen, use the left/right/up/down arrow buttons to select the Non
ROUTE option. You are placed in Non ROUTE mode.
Press the User function button. The Non ROUTE “user defined measurement
setup screen displays.
Use the up/down arrow buttons to highlight the Display Format option and press
the right arrow button. A drop-down list displays.
Use the up/down arrow buttons to select Phase and press an Enter button.
Use the up/down arrow buttons to highlight the Input Channel option and press
the right arrow button. A drop down list displays.
Use the up/down arrow buttons to select either CH1 & CH2 or CH2 & CH3 and
press an Enter button.
Configure other User Setup screen parameters as described above.
Press an Enter button once more to enter the running speed and begin data
collection. The Collecting Data dialog displays with a prompt to specify the running
speed at the bottom of the page.
Figure A - 11.
Collecting Data Screen with Running Speed Options.
To manually enter the RPM:
There are three options for entering the RPM:
dBase - Take the RPM value from the database if previously assigned to the POINT.
This option only appears if the currently selected POINT in ROUTE
mode has a speed entered.
Type In - Type in the value using the numeric keypad, or
A - 22 SKF Microlog - GX Series
User Manual

Table of Contents