Introduction to the SKF GX Series Microlog
Microlog System Connections
Pin-out CH1 Pin-out CH2 USB H/CH R USB DEV/TRIG/PWR
1 CHANNEL 1 1 CHANNEL 2 1 CHANNEL 4 1 EXT-DC-IN
2 CHANNEL 2 2 NC 2 USB VBUS 2 USB Device D +
3 Strobe Out 3 Digital Gnd 3 USB Host D+ 3 USB Device D-
4 CHANNEL 4 4 CHANNEL 3 4 USB Host D- 4 Digital Gnd
5 Analog Gnd 5 Analog Gnd 5 Gnd 5 EXT-TRIG-AUX
6 CHANNEL 3 6 +5V-Tacho Out 6 Audio Out 6 USBV
7 Analog Gnd 7 +5V-Tacho Out
Microsoft
ActiveSync Communications
The procedures in this document require a USB connection between your Microlog and
host PC. If you have not previously connected to your Microlog, you should first verify
that ActiveSync (Win XP) or Mobile Device Centre (Win 7) is installed on your PC. If it is
not, you must download and install it. There are also specific drivers that must be
installed for communication with the Microlog. (See below for details.)
Installing ActiveSync, or Mobile Device Centre
To download a free version of Microsoft ActiveSync (XP), or Mobile Device Centre (Win
7) and for details on how to use them, contact the Microsoft Corporation via their
website at www.microsoft.com
. Run the installation program and follow the on-screen
instructions.
Once installed, you must configure ActiveSync, or Mobile Device Centre to communicate
through the USB port. To do so, select the File menu’s Connection Settings option and
enable the Allow USB connection… option.
USB Drivers for Microlog
To facilitate communication between the Microlog and a host PC, you must first install
specific Windows driver files onto the host PC.
To install the driver files:
• Run the SKF USB Driver Installer v#.##.###.msi installer from the Product CD’s
USB Driver folder to copy the driver files to the PC in a known location.
• Once installed, connect the Microlog to the PC using the CMAC 5095/CA-38
USB/Power Splitter Cable or by placing the unit on the docking station.
• Windows will now complete the device installation.
• On Win 7, you will be notified of driver installation completion in the status area.
SKF Microlog - GX Series 1 - 25
User Manual