9
Conformance Check Module
Overview
The Microlog GX’s Conformance Check Module is used by personnel who wish to
perform before-and-after type vibration level tests for pass / fail conformance in
accordance with an appropriate ISO, ANSI, API or other standard, including vibration
level standards defined by the user. Examples for its use are:
A motor rewind shop tests motors before-and-after overhaul to verify and
document vibration level improvement and conformance to an appropriate
standard.
A manufacturer’s vibration level check to an appropriate conformance standard on
newly manufactured machinery or machinery components prior to delivery.
A maintenance department’s vibration level checks on newly assembled equipment,
or for before-and-after vibration level checks on repaired equipment.
In addition, the Microlog GX’s conformance monitoring ability provides a documented
audit trail of machinery vibration levels (e.g., for comparison between “as delivered” and
“as received” vibration levels).
The Microlog GX is intended for use by:
Installation Engineers
Mechanics
Commissioning Engineers
Maintenance Engineers
Fitters
Inspection Engineers
Servicing Personnel
Noise & Vibration Specialists
Conformance test settings are specified in “test template files” that are transferred to
the Microlog GX. A variety of pre-configured test templates are available from your
local SKF sales representative. These pre-configured test templates measure machinery
vibration in accordance with a recognized international standard (e.g., ISO, ANSI, API,
etc.). Each test template defines a standard’s vibration level measurements for a
specific machinery classification, and the measurement grade levels to which
measurement results are compared.
You may apply these conventional test templates with their standardized measurement
grade settings, or you may use a host computer with the supplied Conformance Check
Setup Generator software (CC Setup software) to modify the standardized test
template settings to more accurately apply to your machinery vibration conformance
SKF Microlog - GX Series 9 - 1
User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF Microlog GX Series and is the answer not in the manual?

SKF Microlog GX Series Specifications

General IconGeneral
BrandSKF
ModelMicrolog GX Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals