The Analyzer Module
How to Collect Standard Vibration Measurements
Function Buttons
Help Press the Help function button to quickly view on-line help for Microlog data
collection.
Setup Highlight an Analyzer measurement icon and press the Setup function button
to access the highlighted measurement’s setup screen, where you may alter the
measurement’s default settings and then start the measurement.
Start Highlight an Analyzer measurement icon and then press the Start function
button to immediately start the highlighted measurement using its default settings.
Back Exit the Analyzer screen and return to the main menu screen.
Press the Shift button (0 / up arrow) to access alternate function buttons:
Review Displays the Analyzer Load Setup screen where you may review previously
saved Analyzer measurement results and saved measurement setups.
Cont. -Press the Cont.- function button to decrease graphic display contrast.
Cont. + Press the Cont. + function button to increase graphic display contrast.
How to Collect Standard Vibration Measurements
The standard vibration measurements all work similarly in how they are applied. We’ll
use the acceleration measurement to example their use.
Collecting Measurements Using the Default Measurement Setup
Standard vibration measurements may be quickly applied using their factory default
settings, or you may change their settings and then perform the measurement. We’ll
first describe how to perform standard measurements using their default
configurations.
To perform a standard acceleration measurement (using its default settings):
From the Analyzer screen use the arrow keys to highlight the Acceleration icon,
and press the Start function button. The measurement is performed and the initial
measurement results display.
If you highlight a measurement’s icon and press the Enter (Fire)
button instead of the Start function button, you will display the
measurement’s setup screen, not start the measurement.