Machinery Balancing Module
How to Perform a 1-2 Plane with Prognosis Procedure
If you press the 2-Plane function button, the dynamic 2 plane balancing procedure
resumes. Reference the previous How to Perform a Dynamic 2 Plane Procedure
section for instructions on how to complete the 2-plane procedure.
If you press the 1-Plane function button, in following 2 plane Correction Run screens,
all Plane B / CH2 fields are marked as N/A (not applicable).
Add a Correction Weight to Plane A
Figure 5 - 37.
Example of a 2-Plane Correction Weight Screen When You
Select to Proceed with a 1-Plane Prognosis.
Now the Correction Weight screen displays the permanent Correction weight, Angle,
and Radius balance solutions for Plane A at the top of the screen (Plane B settings are
marked N/A), and correction weight options at the bottom.
Stop the machine, remove the temporary trial weights (if appropriate), and securely
attach the permanent correction weights at the precise angles and radii specified.
The Split Weight, Add/Remove, Correction, and Combine All fields and the Actual
function button all operate as described in the previous How to Perform a Single-
Plane Procedure section.
In all Correction Weight fields, use the up / down / right / left
arrow buttons to move between fields.