EasyManua.ls Logo

SKF Microlog GX Series - Waterfall Plot Display

SKF Microlog GX Series
342 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Run Up / Coast Down Module
Displaying Acquired Data
Waterfall Plot Display
For analysis purposes, setup options for how to best process and display the recorded
data for each display format are specified by the user prior to data display.
Waterfall Analysis Setup
From the RUCD Display Select menu, use arrow keys to highlight the Waterfall
icon, and press an Enter button. The RUCD Waterfall Setup screen displays.
Figure 7 - 12.
The Waterfall Setup Screen.
Waterfall analysis setup fields include:
Channels If multiple channels were recorded, specify which channel’s data to display
in the Bode plot.
Start Spd / Stop Spd (RPM)For the recorded data, determines the start and stop
speeds for Waterfall plot analysis.
Spacing (
RPM, %
RPM,
Time,
RPM +
Time, %
RPM +
Time) -
Determines
the type of interval used when FFT spectra are calculated from the
recording. Affects subsequent Speed Interval and Time Interval settings, which
update to allow corresponding settings.
RPM fixed speed change between spectra
%
RPMpercentage speed change between spectra
Timefixed time interval between spectra
RPM +
Time - Combination of speed and time settings. If speed stops
changing, then spectra are calculated at the defined time interval.
%
RPM +
Time - Combination of speed and time settings. If speed stops
changing, then spectra are calculated at the defined time interval.
SKF Microlog - GX Series 7 - 15