Machinery Balancing Module
How to Perform a Single-Plane Procedure
Figure 5 - 13.
Example of Multiple Trial Runs.
In the Balancing Summary table:
(re indicates “removed”
(sel … indicates “selected
(pro … indicatesproposed”
To proceed with the balancing job:
From the Trial Run screen, press an Enter / Fire button to proceed. Before
computing the correction weight solution, you are prompted to indicate whether the
trial weight is to remain attached or be removed.
Trial weights are normally temporary, and removed before one
final correction weight is attached. However, sometimes the trial
weight must be permanently attached for safety purposes, and is
therefore left on the machine.
SKF Microlog - GX Series 5 - 19
User Manual