The Analyzer Module
How to Perform Multi-Channel Measurements
Two Channel Spectrum+Cross-Channel Phase Displays
Figure 4 - 18.
A Two Channel Spectrum+Cross-Channel Phase Display Screen.
A cross-channel phase measurement displays the spectra for input channels 1 & 2, and
the relative phase angle between the two input channels. Note that the phase
difference between the two inputs is measured. This is known as relative phase.
Spectra for both input channels are stored, and the relative phase between the two
channels is displayed on the spectrum or as a table of magnitude/phase pairs of up to 8
orders of running speed. In a two channel Spectrum+Cross-Channel Phase display,
the initial two traces display the FFT and phase of input CH1 relative to input CH2.
View menu options are:
FFT for CH1, 2
Power Cepstrum for CH1, 2
Power Spectrum for CH1, 2
FFT for CH1
FFT for CH2
FFT+Power Cepstrum for CH1
FFT+Power Spectrum for CH1
FFT+Power Cepstrum for CH2
FFT+Power Spectrum for CH2