Run Up / Coast Down Module
How to Set Up a RUCD Measurement
Figure 7 - 2.
The RUCD Screen.
RUCD menu options are:
Recall – Recalls the setup screen for the last RUCD measurement that was taken
(whether it was saved or not).
General Run Up – Initiates a run up measurement using default settings.
General Coast Down – Initiates a coast down measurement using default settings.
New - Provides another way to set up a new “user defined” RUCD measurement.
Review –Initiates the RUCD – Load Setup screen allowing you to review previously
saved RUCD measurement data or saved RUCD measurement setups.
Function Buttons
Function buttons at the bottom of the RUCD screen include:
Help – Displays the Microlog’s context sensitive help screen.
Setup – Displays the measurement setup screen for the highlighted measurement type
(i.e., Recall, General Run Up, General Coast Down, or New).
Start – Take RUCD data using the currently highlighted icon’s settings.
Back – Returns you the Microlog’s Main Menu screen.
SKF Microlog - GX Series 7 - 3
User Manual