Machinery Balancing Module
How to Perform a Dynamic 2 Plane Procedure
Add the Correction Weight
Figure 5 - 28.
The Correction Weight CW 1 Screen.
The Correction Weight screen displays the permanent Correction weights, Angles, and
Radii balance solutions for both planes at the top of the screen, and correction weight
options at the bottom.
Stop the machine, remove the temporary trial weights (if appropriate), and securely
attach the permanent correction weights at the precise angles and radii specified.
The Split Weight, Add/Remove, Correction, and Combine All fields and the Actual
function button all operate as described in the previous How to Perform a Single-
Plane Procedure section.
In all Correction Weight fields, use the up / down / right / left
arrow buttons to move between fields.
SKF Microlog - GX Series 5 - 35