19/23
8.21. A34 Wave type
It defines the course of output voltage.
full wave
half wave -equivalent of unidirectional rectification
8.22. A35
Unused parameter for this type of controller.
8.23. A36 Switch ON
States how the controller behaves after connecting
the supply voltage.
Press button - After connecting the supply voltage,
the controller is off. It is activated by
pressing the button
ON
/
OFF
.
Automatic - After connecting the supply voltage the
controller is automatically activated. This
setting does not exclude activation and
deactivation by pressing.
8.24. A37 Service functions
For servicing.
Not used – Service functions are not activated.
RND stop – When testing the feeder actual operational
behaviour can be simulated. The feeder is
disconnected and connected at irregular
intervals.
8.25. A38 Lock/unlock
Use this parameter to lock or unlock the editing of
parameters A10 - A16. First, type the password by
parameter A41 (Chapter 8.28.). Then, using the + or
- button set the number of the parameter to be locked
or unlocked. Press the
enter
button. The key icon appears
after the parameter number. This means that the
selected parameter is locked. It can be unlocked in the
same way. By pressing the
enter
button the key icon
disappears and the parameter is unlocked. Parameters
are locked if the password is disabled.