Do you have a question about the Skipala DIGR-1502/E and is the answer not in the manual?
| Brand | Skipala |
|---|---|
| Model | DIGR-1502/E |
| Category | Controller |
| Language | English |
Details the controller's installation in horizontal or vertical position, mounting, and drilling requirements.
Instructions for unscrewing the controller lid using M3 screws for access.
Connects the controller's power section to a standard 230V socket via a circuit breaker.
Details connecting sensors, valves, digital and analogue signals to the control section.
Instructions for reassembling the controller's lid and parts after connections are made.
Describes the controller's operational statuses: Energized, STOP, RUN, and WAIT.
Methods for turning the controller on, either manually or automatically after power connection.
Describes the controller's operational modes, R-run (operation) and S-stop (standby).
Guides on selecting, modifying, and saving parameter values using the control panel.
Defines the output voltage amplitude range and its dependence on power supply voltage.
Controls the output voltage frequency within a specified range of 20-120 Hz.
Parameters for controlling delays related to sensor signals and feeder status.
Adjusts the amplitude change rate during feeder start-up and shut-down.
Sets times for batch supply and pauses between batches for intermittent operation.
Restricts the maximum and minimum amplitude settings for the output voltage.
Determines the function of digital input IN1, including 'Start', 'Maximum stock', and 'Ejector IN'.
Specifies the type of sensor connected to digital input IN1 (Normal Open or Normal Close).
Determines the use of digital input IN2, similar to input IN1.
Specifies the type of sensor connected to digital input IN2.
Configures the analogue input AIN for 0-10V operation or as a digital 0/24V input.
Defines the function of digital output OUT1, such as 'Run status', 'Air jet', or 'Ejector E1'.
Universal timers for use determined by parameter A24 (Output OUT1).
Defines the function of digital output OUT2, utilizing timers T21, T22, T23.
Universal timers for use determined by parameter A28 (Output OUT2).
Parameters reserved for future use.
Defines the course of the output voltage, choosing between full wave and half wave.
Unused parameter for this specific controller model.
Determines controller behavior after power supply connection (Press button or Automatic).
Configures service functions, including 'Not used' and 'RND stop' for testing.
Allows locking or unlocking of parameters A10-A16 using a password.
Enables language selection for the controller interface (English, Czech, etc.).
Provides information on where to find more details about the product, including a website.
Details on using and managing the password for parameter security.
Procedure to reset all controller parameters to their default factory settings.
Guidance on controller maintenance, fuse replacement, and troubleshooting via parameter reset.
Instructions for the professional disposal of the controller at the end of its service life.
Details the product's guarantee period and fields for serial number, seller, and date of sale.
Official declaration of the product's conformity with EU directives and harmonized standards.