SkyAzúl,EquipmentSolutionswww.skyazul.com301‐371‐6126
Informationdisplayshowsletterc:
TEXT: “c=1”
Customer Options not registering to
the CPU OR Telescope section Nol
not locke
TEXT: “c=2”
Telescope section 2 not locked
Central unit faulty.
Call SkyAzul: 301-228-6086
YES
Inspect components & bus lines
from -customer options for -damage
/ faulty connections OR Lock /
inspect locking mechanism of tele
section 1
Lock/inspect locking mechanism of
tele section 2
YES
NO
NO
NO
TEXT: “c=3”
Telescope section 3 not locked
Lock/inspect locking mechanism of
tele section 3
YES
NO
TEXT: “c=4”
Telescope section 4 not locked
Lock/inspect locking mechanism of
tele section 4
YES
NO
TEXT: “c=6”
Local statutory 'Options not
registering with CPU i.e.O/R's -
extended
& down
France
Operate the option as required by
regulations OR inspect the monitoring
YES
NO
TEXT: “c=7”
Slewing angle restriction
Return crane to defined “arc” as per
load chart
YES
NO
TEXT: “c=8”
Turntable locking pin not engaged
Ensure slew lock pin is engaged
correctly with super over the rear OR
check switches
& bus line for fault
YES