Electrocution Hazard
This aerial platform is not electrically insulated. Maintain a Minimum Safe Approach Distance (MSAD) from energized
power lines and parts as listed below. The operator must allow for the platform to sway, rock or sag. This aerial
platform does not provide protection from contact with or proximity to an electrically charged conductor.
Per ANSI A92.5-2006 8.10(7)
“The operator shall perform only the work for which he or she is qualied, in compliance with all applicable safety
related work practices intended to prevent electric shock covered by the Code of Federal Regulations (CFR) 1910.333.
The operator’s level of competence shall be established only by persons qualied to do so. Operators shall
maintain the appropriate minimum approach distance (MAD) from energized power lines and parts covered by
CFR 1910.333 (c).”
Unqualied persons must maintain a minimum approach distance of 10 feet from any energized power line up to
50 kV. Energized power lines over 50 kV require a greater minimum approach distance to be maintained. Refer to
CFR 1910.333.
As per CSA B354.4-02
“The operator shall maintain the minimum safe approach distance (MSAD) from energized conductors at all times
in accordance with the authority having jurisdiction.”
Refer to CFR 1910.333 or the authority having jurisdiction.
DO NOT USE AERIAL PLATFORM AS A GROUND FOR WELDING.
DO NOT OPERATE AERIAL PLATFORM DURING LIGHTNING OR STORMS.
DO NOT OPERATE THE AERIAL PLATFORM NEAR POWER LINES. MAINTAIN A MINIMUM SAFE
APPROACH DISTANCE (MSAD) FROM ENERGIZED POWER LINES.
Voltage Range Minimum Safe Approach Distance
(Phase to Phase) (Feet)
0 to 300V Avoid Contact
Over 300V to 50KV 10
Over 50KV to 200KV 15
Over 200KV to 350KV 20
Over 350KV to 500KV 25
Over 500KV to 750KV 35
Over 750KV to 1000KV 45
60023AD-ANSI
DANGER
FAILURE TO AVOID THIS HAZARD WILL RESULT IN DEATH OR SERIOUS INJURY!
Avoid Power Lines
Minimum Safe Approach Distance
ANSI/SIA A92.6-2006 & CSA B354.2-01 Requirements
SJ 40T & SJ 45T
SJ 61T & SJ 66T
Page 7
Section 1 - About Your Aerial Platform Safety Rules

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skyjack SJ40T and is the answer not in the manual?

Skyjack SJ40T Specifications

General IconGeneral
BrandSkyjack
ModelSJ40T
CategoryBoom Lifts
LanguageEnglish

Related product manuals