Section 4 – Inspections Before Operation Visual and daily maintenance inspections
4.2-9 Boom assembly
Do the inspection that follows, and make sure:
1
Load cell
There are no loose or missing parts, and there
is no visible damage.
All fasteners are correctly tightened.
All cables are in good condition and not loose.
There is no debris between the platform and
the boom adaptor.
2
Rotary actuator
There are no loose or missing parts, and there
is no visible damage.
All fasteners are correctly tightened.
All hoses are correctly tightened and there is
no sign of hydraulic leakage.
3
Jib (if equipped)
There are no loose or missing parts, and there
is no visible damage.
All fasteners are correctly tightened.
All hoses are correctly tightened and there is
no sign of hydraulic leakage.
4
Cable Track
There are no loose or missing parts, and there
is no visible damage.
5
Cylinders
Make sure the cylinders are correctly installed.
Make sure there is no indication of leaks or
damage.
6
Wear pads
All fasteners are correctly tightened.
There are no loose or missing parts, and there
is no visible damage to the wear pads.
7
Boom
There are no loose or missing parts, and there
is no visible damage.
All fasteners are correctly tightened.
All hoses are correctly tightened and there is
no sign of hydraulic leakage.
Hoses
All hoses are correctly tightened and there is
no sign of hydraulic leakage.