EasyManuals Logo

Slant/Fin Intrepid TR Series User Manual

Slant/Fin Intrepid TR Series
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
TR 20
TR 30
TR 40
TR 50
TR 60
TR 70
292
378
464
549
635
721
11 1/2
14 7/8
18 1/4
21 5/8
25
28 3/8
210
255
298
341
383
426
8 9/32
10 1/32
11 23/32
13 13/32
15 3/32
16 25/32
152¶
152¶
178
203
203
229
7
8
8
9
38
38
38
38
38
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
616
702
787
873
959
1172
24 1/4
27 5/8
31
34 3/8
37 3/4
46 1/8"
Boiler Model Boiler Length “A
mm in
Front to Flue “B”
mm in
Flue Diameter “C
mm in
Circulator Flange
mm in
Overall Length “E”
mm in
2 TR Series
Note: Standard working pressure 207 kPa (30 psi) water, 103 kPa
(15 psi) steam.
* ADD SUFFIX
X Denotes no circulator and no thermostat
P Packaged water boiler
PT Packaged water boiler with tankless heater
PZ Packaged steam boiler less tankless heater
PZT Packaged steam boiler with tankless heater
§ Tankless heater rating based on intermittent draw.
§§ Nominal clay tile liner dimensions.
For forced hot water heating systems where the boiler and
all piping are located within the area to be heated, the boiler
may be selected on the basis of gross output capacity. The
net output ratings shown are based on an allowance for
piping and pickup of 1.15 (water) or 1.33 (steam). Gross
output is divided by the allowance to obtain net rating. The
manufacturer should be consulted before selecting a boiler
for unusual piping and pickup requirements such as inter
mittent system operation, extensive piping, etc.
Note: m
2
of steam is equal to net output (W) divided by
757 W (square feet of steam is equal to net output (BTU)
divided by 240 BTUs)
Ratings apply to the use of light oil at 11,000 W/L (140,000
Btu per gallon), and apply only when burner models listed
on pages 15 17 of this manual are used, and are properly
adjusted to produce 13% CO
2
.
TR 20 Collar is oblong, will fit 152 mm (6") diameter nomi
nal connector.
Tapping
Location Steam Boiler Water Boiler
1 76 mm (3”) supply 38 mm (1-1/2”) supply
1A 51 mm (2”) supply on rear section
2 second 6 mm (1/4”) siphon & pressure 19 mm (3/4”) air vent or expansion tank
cut-out if required
3 19 mm (3/4”) steam safety valve 19 mm (3/4”) water relief valve
4 6 mm (1/4”) siphon, pressure gauge &
pressure cut-out
5A 13 mm (1/2”) tankless inlet
5B 13 mm (1/2”) tankless inlet
6 6 mm (1/4”) pressure temp. gauge
7 13 mm (1/2”) high limit, hi/lo or
combination control
8 19 mm (3/4”) alternate electronic low
water cut-off
9 38 mm (1-1/2”) skimmer tapping
10 13 mm (1/2”) low limit for tankless
11A 13 mm (1/2”) tankless inlet
11B 13 mm (1/2”) tankless outlet
12 13 mm (1/2”) steam gauge glass & 67 LWCO
13 38 mm (1-1/2”) bushed to 19 mm (3/4”) for drain cock 38 mm (1-1/2”) return &
19 mm (3/4”) drain cock
14 38 mm (1-1/2”) condensate return 38 mm (1-1/2”) alternate return
15 3/4” NPT zone tapping
102mm
(14”)
810 mm (31-7/8")
445 mm (17-1/2")
32 mm (1-1/4")
95 mm (3-3/4")
635 mm
(25")
372 mm
(14-5/8")
648 mm
(25-1/2")
44 mm
(1-3/4")
DRAIN COCK
(Alternate 38 mm
(1-1/2") Tapping
for additional
circulator.)
RATINGS WITH RIELLO BURNER
89 mm (3-1/2")
LEFT END – WATER & STEAM
Water
Figure 1
Figure 2
Steam
1 1
Boiler
Model
Number
*
OIL INPUT
HEATING CAPACITY
OUTPUT
BURNER NET RATINGS CHIMNEY SIZE AFUE %
Boiler
Sections
TANKLESS HEATER
§
ml/s USGPH kW MBH
Water Steam Water‡ Steam Steam I.D I.D.ROUND
Water Steam
Water Steam
kW MBH kW MBH kW MBH kW MBH Sq.Ft. mm in. mm in. ml/s USGPM ml/s USGPM
TR 20 0.79 0.75 31 105 27 91 23 79
203 x
203 x
4.6m
8" x 8"
x 15'
127 x
4.6 m
5' x 15' 83.50 2 139 2.20
TR 30H 1.05 1.00 41 140 35 121 31 105
152 x
4.6m
6" x15'
86.00 3 189 3.00
TR 30
1.15 1.10 45 154 40 134 40 131 35 117 30 101 39 421 84.85 84.15 3 202 3.20 189 3.00
1.31 1.25 51 175 45 151 39 131 83.50 214 3.40
TR 40H 1.58 1.50 62 210 53 182 52 179 46 158 39 134 52 558 86.00 84.00 4 240 3.80 215 3.40
TR 40
1.68 1.60 66 224 58 195 58 195 50 170 43 146 56 608
178 x
4.6m
7" x 15'
84.45 84.80 4 221 3.90 221 3.50
1.89 1.80 74 252 64 218 56 190 83.33 261 4.15
TR 50H 2.10 2.00 82 280 71 243 70 239 62 211 52 179 69 746
203 x
4.6m
8" x 15'
86.00 84.00 5 278 4.40 246 3.90
TR 50
2.20 2.10 86 294 76 266 75 255 66 223 56 191 74 796 84.06 83.45 5 277 4.40 252 4.00
2.47 2.35 96 329 80 272 67 237
203 x
305 x
4.6m
8" x 12"
x 15'
296 4.70
TR 60
2.73 2.60 107 364 88 298 88 298 77 259 66 224 87 933
254 x
4.6m
10" x
15'
6 309 4.90 284 4.50
3.00 2.85 117 399 97 327 84 284 328 5.20
TR 70
3.26 3.10 127 434 104 352 105 354 90 306 79 286 103 1108 7 343 5.45 315 5.00
3.52 3.35 137 469 113 381 98 331 359 5.70

Other manuals for Slant/Fin Intrepid TR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Slant/Fin Intrepid TR Series and is the answer not in the manual?

Slant/Fin Intrepid TR Series Specifications

General IconGeneral
BrandSlant/Fin
ModelIntrepid TR Series
CategoryBoiler
LanguageEnglish

Related product manuals