CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PAGE
Ratings and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3
Installation Requirements:
Boiler Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 4
Chimney Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Blocked Vent Safety Switch . . . . . . . . . . . . . . . . . . . . . . . . .5
Air Supply and Venting . . . . . . . . . . . . . . . . . . . . . . . . . . .5 7
Controls and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Piping for Steam Boilers . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Cleaning Piping System . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Piping for Water Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 9
Piping for Tankless Heater . . . . . . . . . . . . . . . . . . . . . . . . . .9
Installing Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Oil Supply Piping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Wiring the Boiler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Vent Piping and Draft Regulator . . . . . . . . . . . . . . . . . . . . .10
Operating Instructions:
Precautions Before Starting . . . . . . . . . . . . . . . . . . . . . . . .10
Start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Cleaning and Filling New Water Boiler . . . . . . . . . . . . . . . .10
Cleaning and Filling New Steam Boiler . . . . . . . . . . . .10 11
Blowing Off a Steam Boiler . . . . . . . . . . . . . . . . . . . . . . . . .11
Low Water Cut-off Check-out . . . . . . . . . . . . . . . . . . . . . . .12
Pressure Control Check-out . . . . . . . . . . . . . . . . . . . . . . . .12
Replacement of Steam Boiler . . . . . . . . . . . . . . . . . . . . . . .12
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 17
Burner Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 20
Care and Maintenance:
Extended Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Freezing Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Oil Burner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
General Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Appendix
B, C & D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
SAFETY WARNING:
KEEP BOILER AREA CLEAR AND FREE FROM COM -
BUSTIBLE MATERIALS, GASOLINE AND OTHER FLAM-
MABLE VAPORS AND LIQUIDS. FAILURE TO ADHERE TO
ABOVE SAFETY WARNING, MAY RESULT IN PERSONAL
INJURY OR DEATH AND PROPERTY DAMAGE.
Printed in Canada 1014 Publication No. TR 40
Part No. 43 2764 Revision L
INSTALLATION AND OPERATING INSTRUCTIONS
OIL-FIRED WATER AND STEAM BOILERS/NO. 2 OIL
INTREPID
IMPORTANT: The installation of this appliance must conform
to the requirements of the authority having jurisdiction or, in
the absence of such requirements, to the Installation of Oil
Burning Equipment, CSA B139. The installation must also
conform to the additional requirements in this Slant/Fin
Instruction Manual. Where there is any difference, the more
stringent requirement shall govern.
Do not use gasoline crankcase drainings or any oil contain-
ing gasoline.
Never burn garbage or paper in this unit, and never leave
combustible material around it.
THIS MANUAL MUST BE LEFT WITH OWNER AND
SHOULD BE HUNG ON OR ADJACENT TO THE BOILER
FOR REFERENCE.
IMPORTANT: This boiler must be installed, serviced and
repaired by a trained, experienced, service technician,
licensed for the installation and servicing of oil-burning hot-
water-heating or steam system equipment or otherwise quali-
fied by the authorities having jurisdiction over the installation.
Heating Contractor
Address
Phone Number
Boiler Model Number
Boiler Serial Number
Installation Date
READ AND SAVE THESE INSTRUCTIONS
FOR REFERENCE
3131567
CONFORMS TO UL STD 726
CERTIFIED TO CAN/CSA STD
B140.7-05

Other manuals for Slant/Fin Intrepid TR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Slant/Fin Intrepid TR Series and is the answer not in the manual?

Slant/Fin Intrepid TR Series Specifications

General IconGeneral
BrandSlant/Fin
ModelIntrepid TR Series
CategoryBoiler
LanguageEnglish

Related product manuals