3 Product Overview
SMA Solar Technology AG
Technical Information 13SMAModbus-ennexOS-TI-en-10
Processing time of parameters
The response time is the time between a query and its answer. For write queries, this is around 1 second per parameter
and for read queries around 500 ms. The response time between the write command via Modbus and the response
via Modbus is up to 1 second. When reading back parameter changes, it is necessary to either wait for the response
or take the response time into account.
request #1: write
response #1
request #2: read
response #2
Modbus
client
SMA
Modbus
server
Reaction time: write
Reaction time: read
Adjust the timeout
in acc. with the number
of parameters written
(~1 s per parameter)
(< 500 ms)
3.7 Number codes of time zones
The following table contains the most important time zones and their number codes in the SMA Modbus profile. If the
location is known, you can determine the numerical key (code) and the time zone. In addition, take account of local
regulations for summer/winter time.
City/Country Code Time zone
UTC-AUTO 9499 AUTO
Abu Dhabi, Muscat 9503 UTC+04:00
Adelaide 9513 UTC+09:30
Alaska 9501 UTC-09:00
Amman 9542 UTC+02:00
Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna 9578 UTC+01:00
Arizona 9574 UTC-07:00
Astana, Dhaka 9515 UTC+06:00
Asuncion 9594 UTC-04:00
Athens, Bucharest, Istanbul 9537 UTC+02:00
Atlantic (Canada) 9505 UTC-04:00
Auckland, Wellington 9553 UTC+12:00
Azores 9509 UTC-01:00
Baghdad, Istanbul 9504 UTC+03:00
Baku 9508 UTC+04:00