6 Electrical Connection
SMA Solar Technology AG
Operating manualSTP50-4x-BE-en-2354
3. Unlock the DC connector. To do this, insert a flat-
blade screwdriver (blade width: 3.5mm) into the
side catch mechanism and pry the catch mechanism
open.
+
2
3
1
4. Carefully pull the DC connector apart.
5. Release the clamping bracket. To do so, insert a flat-
blade screwdriver (blade width: 3.5mm) into the
clamping bracket and pry the clamping bracket
open.
2
+
1
6. Remove the cable.