EasyManua.ls Logo

SMA SUNNY BOY 1700 - Technical Data

SMA SUNNY BOY 1700
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data SMA Solar Technology AG
42 SB11_12_17-IEN094131 Installation Guide
11 Technical Data
PV generator connection data SB 1100 SB 1200 SB 1700
Max. input voltage U
DC Max
400 V
a)
Input voltage, MPP range U
PV
139 V ... 320 V 100 V ... 320 V 139 V ... 320 V
PV start voltage, adjustable U
PV Start
180 V 120 V 180 V
Max. input current I
PV Max
10 A 12.6 A 12.6 A
Max. input power P
DC
1210 W 1320 W 1850 W
Voltage ripple U
PP
< 10 % of the input voltage
Internal consumption during
operation
< 4 W
(standby)
< 4 W
(standby)
< 5 W
(standby)
a) The maximum open circuit voltage, which can occur at a cell temperature of 10 °C, may not exceed the maximum input
voltage.
Grid connection data SB 1100 SB 1200 SB 1700
Nominal output power P
AC nom
1000 W 1200 W 1550 W
Peak output power P
AC max
1100 W 1200 W 1700 W
Nominal output current I
AC nom
4.4 A 5.2 A 6.7 A
Max. output current I
AC max
5.6 A 6.1 A 8.6 A
Max. fuse protection 16 A
Harmonic distortion of output current
(at K
Ugrid
< 2 %, P
AC
> 0.5 P
ACnom
)
K
IAC
< 3 %
Short Circuit Proof grid-side via current regulation
Nominal operating voltage U
AC nom
220 V / 230 V / 240 V
Voltage range
(extended operating range)
U
AC
180 V ... 260 V
Nominal operating frequency f
AC nom
50 Hz / 60 Hz
Frequency range
(extended operating range)
f
AC
50 Hz: 45.5 Hz ... 54.5 Hz
60 Hz: 55.5 Hz ... 64.5 Hz
Power factor (at nominal output
power)
cos ϕ 1
Overvoltage category III
Test voltage (DC) 1.7 kV (1 s routine testing / 5 s type testing)
Test surge voltage 4 kV (serial interface: 6 kV)
Internal consumption in night
operation
0.1 W