Operating Manual SB3-5TL-21-BE-en-10 35
SMA Solar Technology AG 7 Initial Start-Up
Procedure:
☑ The inverter will adopt the setting after commissioning. This can take up to five minutes.
Figure 8: Rotary switch C positions
Item Explanation
0 Bluetooth communication is deactivated.
1 Communication via Bluetooth with another Bluetooth device
2 to F NetID for communication via Bluetooth with multiple Bluetooth devices
1.
Danger to life due to high voltages
• Ensure that the inverter is disconnected from all voltage sources (see Section 10, page 47).
2. To configure a new NetID, set rotary switch C to
the determined NetID using a flat-blade
screwdriver (blade width: 2.5 mm).
3. To deactivate the communication via Bluetooth,
set rotary switch C to the position 0 using a
flat-blade screwdriver (blade width: 2.5 mm).
This protects your PV system from unauthorized
access.