EasyManua.ls Logo

SMA SUNNY BOY 3600TL - Page 35

SMA SUNNY BOY 3600TL
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual SB3-5TL-21-BE-en-10 35
SMA Solar Technology AG 7 Initial Start-Up
Procedure:
The inverter will adopt the setting after commissioning. This can take up to five minutes.
Figure 8: Rotary switch C positions
Item Explanation
0 Bluetooth communication is deactivated.
1 Communication via Bluetooth with another Bluetooth device
2 to F NetID for communication via Bluetooth with multiple Bluetooth devices
1.
Danger to life due to high voltages
Ensure that the inverter is disconnected from all voltage sources (see Section 10, page 47).
2. To configure a new NetID, set rotary switch C to
the determined NetID using a flat-blade
screwdriver (blade width: 2.5 mm).
3. To deactivate the communication via Bluetooth,
set rotary switch C to the position 0 using a
flat-blade screwdriver (blade width: 2.5 mm).
This protects your PV system from unauthorized
access.