58 SB3-5TL-21-BE-en-10 Operating Manual
13 Technical Data SMA Solar Technology AG
13.4 Climatic Conditions
According to IEC 60721-3-4, installation type C, class 4K4H
In Accordance with IEC 60721-3-4, transport type E, class 2K3
13.5 Equipment
Maximum permissible fuse protection for
SB 5000TL-21
32 A
Ground-fault monitoring for SB 3000TL-21 Insulation monitoring: R
iso
> 625
Ground-fault monitoring for SB 3600TL-21 Insulation monitoring: R
iso
> 550
Ground-fault monitoring for SB 4000TL-21 Insulation monitoring: R
iso
> 500
Ground-fault monitoring for SB 5000TL-21 Insulation monitoring: R
iso
> 400
All-pole sensitive residual-current monitoring unit Available
Extended temperature range -25°C to +60°C
Extended humidity range 0% to 100%
Extended air pressure range 79.5 kPa to 106 kPa
Temperature range -25°C to +70°C
DC connection SUNCLIX DC connector
AC connection Spring-cage terminal
Display LC graphic display
Bluetooth As standard
RS485, galvanically isolated Optional
Speedwire/Webconnect data module Optional
Multifunction relay Optional
SMA Power Control Module Optional

Table of Contents