EasyManua.ls Logo

SMA SUNNY BOY 6000TL?US - Cleaning the Ventilation Grids

SMA SUNNY BOY 6000TL?US
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMA America, LLC 6 Cleaning and Care
User Manual SB6-11TLUS-BA-eng-BUS121211 37
6.5 Cleaning the Ventilation Grids
The ventilation grids must be clean for optimum heat dissipation of the device. Clean the ventilation
grids regularly according to the following procedure.
1. Remove the ventilation grids sideways.
3. Clean the ventilation grids with a soft brush, a paintbrush or compressed air.
4. Close the recessed grips with the ventilation grids.
Ensure that the assignment is correct. The correct
enclosure side is marked on the interior of each
ventilation grid: left side "links ⁄ left" and right side
"rechts ⁄ right".
2.
Damage to the inverter caused by foreign bodies.
Do not remove the ventilation grids permanently. This prevents foreign bodies from
entering the enclosure.