Installation Guide SB50US-80US-IUS094030 63
Positive Grounding
3. Torque all wires in the terminal blocks inside the SMA DC-Disconnect to 15 in-lb (1.7 Nm).
To verify that your inverter is grounded as intended please refer to section 5.7"DC Input
Grounding" (page56).
1. Connect the negative DC wires (A) to the terminal
labeled PV UNGROUNDED in the SMA DC-
Disconnect.
2. Connect the positive DC wires (A) to the terminal
labeled PV GROUNDED in the SMA DC-Disconnect.
4. Use a screwdriver in order to poke a hole in the
groove of the grommet.
5. Remove the membrane.