EasyManua.ls Logo

SMA Sunny Boy SB 2500 - Sunny Boy SB 3000; PV Generator Connection Data

SMA Sunny Boy SB 2500
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMA Technologie AG Technical Data
Installation Guide SB25_30-11:SE0307 Page 37
8.2 Sunny Boy SB 3000
8.2.1 PV Generator Connection Data
Description Abbr. Setting
Max. input open circuit voltage U
PV 0
600 V (based on -10 °C cell
temperature)
Input voltage, MPP range U
PV
268 V ... 600 V
Max. input current I
PV, max
12 A
Max. input power P
DC
3200 W
Recommended total generator
power
3600 Wp (for central Europe)
All-pole isolator on the DC input
side
DC plug connector
Overvoltage protection thermally monitored varistors
Voltage ripple U
PP
< 10 % of the input voltage
Insulation protection ground fault monitoring (Riso > 1 MΩ)
Operating consumption < 7 W (standby)
Reverse polarity protection via short-circuit diode

Related product manuals