EasyManua.ls Logo

SMA SUNNY CENTRAL 800CP XT - Page 141

SMA SUNNY CENTRAL 800CP XT
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 Operating Data and Parameters
SMA Solar Technology AG
User Manual 141SCCPXT-E7-BA-en-58
Name Description Value/range Explanation Default
value
Tm Entry of current time 0 to 235959 Entered in the format HH-
MMSS
TolGr1* Deviation of group1 currents
from mean value
5% to 100% Parameter exists for all six
groups.
13%
MoniTm-
Gr1On*
Start time for monitoring of
group1
07:00 a.m. to
7:00 p.m.
Parameter exists for all six
groups.
10:00 a.m.
MoniTm-
Gr1Off*
End time for monitoring of
group1
07:00 a.m. to
7:00 p.m.
Parameter exists for all six
groups.
3:00 p.m.
MoniTmGrAl-
lOn*
Start time for monitoring of all
groups
07:00 a.m. to
7:00 p.m.
10:00 a.m.
MoniTm-
GrAllOff*
End time for monitoring of all
groups
07:00 a.m. to
7:00 p.m.
3:00 p.m.
MoniTm-
ComOn*
Start time for monitoring of all
groups
07:00 a.m. to
7:00 p.m.
10:00 a.m.
MoniTmCo-
mOff*
End time for monitoring of all
groups
07:00 a.m. to
7:00 p.m.
3:00 p.m.
Ackn Acknowledge errors quit
ErrLevGr1* Sensitivity of error detection for
group1
Parameter exists for all six groups
24 Sensitive 50 min ‒ 10% 32 Regular
24 Regular 50 min ‒ 14%
24 Insensitive 50 min ‒ 18%
32 Sensitive 35 min ‒ 10%
32 Regular 35 min ‒ 13%
32 Insensitive 35 min ‒ 16%
64 Sensitive 15 min ‒ 7%
64 Regular 15 min ‒ 9%
64 Insensitive 15 min ‒ 10%
ComBaud* Baud rate 1,200 baud Parameter can only be
changed in the operating state
"Stop".
19,200
baud
4,800 baud
9,600 baud
19,200 baud
38,400 baud
57,600 baud

Table of Contents

Related product manuals