Electrical Connection SMA Solar Technology AG
32 WB33-38-IA-IEN120940 Installation Manual
3. Ensure that the cable is correctly positioned:
4. Push the cable gland up to the thread and fasten to a torque of 2 Nm.
The DC connectors are now assembled and can be connected to the inverter as described in
Section 5.5.4"Connecting the Small Wind Turbine System (DC)" (page34).
Result What to do
If the stranded wire is visible in the chamber
of the clamping bracket, the cable is
correctly positioned.
Proceed to step 4.
If the stranded wire is not visible in the
chamber, the cable is not correctly
positioned.
Release the clamping bracket. Do this by
inserting a screwdriver (blade width: 3.5 mm)
into the clamping bracket to lever it open
.
Remove the cable and go back to step 1.