Maintenance and servicing
Cleaning of filter belt
Instruction manual EBF / EBF ECO page 15 of 19
11/2014
Detergent
Concentration
Resistance
Hydrochloric acid (HCl)
5 %
good
16 %
optimal
20 %
limited
> 35 %
not resistant
Citric acid (C6H8O7)
100 %
very good
Table vinegar
100 %
Very good (our
recommendation)
Hydrogen peroxide (H2O2)
3 %
Very good
Instruction
The selected detergent shall be applied and allowed to have effect for at
least 15 minutes. The filter belt should be as dry as possible.
The water level in the bio-pond should lie below the filter stage (filter
belt).
High-pressure cleaner
The belt can cleaned with high pressure (max. 120 bar) of cold water with
a distance of more than 15 cm, but without any guarantee.
Instruction
The use with a high-pressure cleaner is not guaranteed by the belt
manufacturer and can be carried out at own risk. However, we have
obtained some good results for it in extensive tests.