ITV3000
4000 /min (ANR)
Pressure range: 0.9 MPa, Supply pressure: 1.0 MPa
ITV1000
200 /min (ANR)
ITV2000
1500 /min (ANR)
IP65
Series ITV1000/2000/3000
CAT.ES60-15 -UK
D
Electro-Pneumatic Regulator
Stepless control of air pressure proportional to an electrical signal
200 /min type is newly
introduced to the series.
Oil free specifications
(wetted parts)
Sensitivity:
Linearity: Within (F.S.)
Hysteresis: Within (F.S.)
(100 kPa specifications)

Other manuals for SMC Networks ITV1000 series

Question and Answer IconNeed help?

Do you have a question about the SMC Networks ITV1000 series and is the answer not in the manual?

SMC Networks ITV1000 series Specifications

General IconGeneral
BrandSMC Networks
ModelITV1000 series
CategoryController
LanguageEnglish

Summary

Standard Specifications

Model and Specification Details

Details of models, pressure ranges, power supply, input signals, and output characteristics.

How to Order

Guidance on selecting and ordering the correct regulator configuration.

Combinations and Accessories

Modular Product Combinations

Information on combining modular products and accessories for system integration.

Optional Accessories

List of optional accessories with their corresponding part numbers for customization.

Working Principles

Working Principle Diagrams

Visual representations of the regulator's internal operation and signal flow.

Block Diagram

Schematic overview of the control system and signal paths.

ITV101 Performance Characteristics

ITV101 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV101.

ITV101 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV101.

ITV201 Performance Characteristics

ITV201 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV201.

ITV201 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV201.

ITV301 Performance Characteristics

ITV301 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV301.

ITV301 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV301.

ITV103 Performance Characteristics

ITV103 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV103.

ITV103 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV103.

ITV203 Performance Characteristics

ITV203 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV203.

ITV203 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV203.

ITV303 Performance Characteristics

ITV303 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV303.

ITV303 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV303.

ITV105 Performance Characteristics

ITV105 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV105.

ITV105 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV105.

ITV205 Performance Characteristics

ITV205 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV205.

ITV205 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV205.

ITV305 Performance Characteristics

ITV305 Linearity, Hysteresis, Repeatability

Graphs detailing linearity, hysteresis, and repeatability for ITV305.

ITV305 Pressure, Flow, Relief

Graphs detailing pressure, flow, and relief characteristics for ITV305.

ITV10 Dimension Details

ITV10 Bracket Mounting

Details for flat and L-bracket mounting configurations for the ITV10 series.

ITV20 Dimension Details

ITV20 Bracket Mounting

Details for flat and L-bracket mounting configurations for the ITV20 series.

ITV30 Dimension Details

ITV30 Bracket Mounting

Details for flat and L-bracket mounting configurations for the ITV30 series.

Made to Order Specifications

Ozone Resistant and Preset Input Types

Options for ozone resistance and 16-point preset input functionality.

Digital Input, DeviceNet, and N.C. Types

Specifications for digital input, DeviceNet compliance, and normally closed (N.C.) types.

High Pressure and Other Options

Includes high pressure, analogue output, pressurized enclosure, and manifold options.

Manifold Specifications and Ordering

Manifold Configurations

Details on manifold configurations for 2 to 8 station assemblies.

How to Order Manifolds

Instructions for ordering manifold assemblies and components.

High-Speed Response Time

Specifications for high-speed response time and related ordering codes.

Safety Instructions

General Safety Warnings

Important warnings regarding compatibility, trained personnel operation, and service safety.

Special Use Conditions

Guidelines for contacting SMC for specific environments or applications requiring safety analysis.

Precautions - Piping and Environment

Piping Precautions

Guidelines for proper piping connection, torque, and tubing use.

Operating Environment Precautions

Warnings for operating in hazardous atmospheres, vibration, sunlight, or near heat sources.

Air Supply Precautions

Recommendations for air supply quality and avoiding chemical contamination.

Specific Product Precautions 1

Operating Environment and Air Supply

Precautions for operating environment, air supply filtration, and quality.

Handling Precautions

Guidelines for handling, power interruption, disassembly, and cable connector use.

Specific Product Precautions 2

Wiring and Noise Avoidance

Instructions for correct wiring, connector handling, and noise reduction measures.

Set Pressure Range

Table detailing regulating pressure ranges by unit of standard measured pressure.

Related product manuals