Installation
187
EN
The nozzles not provided are available at Authorised Service Centres.
8 Liquid gas – G30/31 - 30/37 mbar AUX SR R DUAL int + ext
Rated heating capacity (kW)
1.01.752.9 4.2
Nozzle diameter (1/100 mm)
50 65 85 46 + 91
Pre-chamber (printed on nozzle)
--- -
Reduced flow rate (W)
400 500 800 1900
Rated flow rate G30 (g/h)
73 127 211 305
Rated flow rate G31 (g/h)
71 125 207 300
9 LPG G30/31 - 37 mbar AUX SR R DUAL int + ext
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
50 65 81 46 + 85
Pre-chamber (printed on nozzle)
--- -
Reduced flow rate (W)
450 550 800 1900
Rated flow rate G30 (g/h)
73 131 211 305
Rated flow rate G31 (g/h)
71 129 207 300
10 LPG G30/31 - 50 mbar AUX SR R DUAL int + ext
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
43 58 70 43 + 70
Pre-chamber (printed on nozzle)
(H2) (M) (Z) (H2) + (S1)
Reduced flow rate (W)
400 500 800 1900
Rated flow rate G30 (g/h)
73 131 211 305
Rated flow rate G31 (g/h)
71 129 207 300
11 Town gas G110 – 8 mbar AUX SR R DUAL int + ext
Rated heating capacity (kW)
1.0 1.8 2.8 3.7
Nozzle diameter (1/100 mm)
145 185 260 140 + 320
Pre-chamber (printed on nozzle)
/8 /2 /3 -
Reduced flow rate (W)
400 500 800 1400
12 Town gas G120 – 8 mbar AUX SR R DUAL int + ext
Rated heating capacity (kW)
1.1 1.8 2.9 3.8
Nozzle diameter (1/100 mm)
145 185 260 130 + 290
Pre-chamber (printed on nozzle)
/8 /2 /3 -
Reduced flow rate (W)
400 500 800 1400